ID media are sent in the same format as set for the standard operating
mode. When the reader module operates in the Wiegand output operating mode, the I/O
Port (tab. 6) is used as an input for monitoring an external device tamper status.
ID media technology
EM Marin
HID Proximity
Two long beeps and the red LED lit feature powering up the module. The green LED blink
indicates an ID reading.
Individual signals function in
Input 1
Input 2
Output 1 (relay)
Since the
FW version 5.09
is implemented, enabling to
module offers the
Wiegand data interface synchronization
6.6.3 Wiegand input (entry reader)
The module can be configured into a mode of controlling the door from both sides
reader
mode).
In the
entry reader mode
WIEGAND interface
operates standardly, the reason codes equal zero.
When the reader module operates in the entry reader operating mode, the I/O Port (tab. 6)
is used as an output for controlling the entry reader buzzer.
Since the
FW version 5.09
is implemented, enabling to
module offers the
Wiegand data interface synchronization
The
WIEGAND input
Available configuration of the WIEGAND output format
26bit, 32bit, 42bit, 44bit
Automatically recognized format / 45bit raw data
User configuration
Table 10: ID media format in WIEGAND operating mode
WIEGAND output
Beeper control (0 V active)
Yellow LED control (0 V active)
Tamper signaling; it follows the alarm state of tamper
sensors (tamper signal = relay switched on)
Table 11: Signal function in WIEGAND operating mode
the reading synchronization of a
cancel the mutual disturbance
an identification at an external reader connected via the
acquires a
reason code
the reading synchronization of a
cancel the mutual disturbance
and
WIEGAND output
Page 12
operating mode is described in table 11.
couple of TECHFASS readers
of the modules. The reader
in
MASTER
255; at the same time the reader module
couple of TECHFASS readers
of the modules. The reader
in
SLAVE
operating modes are mutually exclusive.