Adjustments - Cecilware ME10EN Operator's Manual

Hide thumbs Also See for ME10EN:
Table of Contents

Advertisement

Adjustments

Thermostat Adjustment
The Thermostat is factory set for proper dispense
temperature of 200°F ± 3°F (93°C ± 16°C) with the
control knob set to the maximum clockwise position. If
field adjustments are needed proceed as follows:
• To DECREASE temperature, turn the control knob
slightly in the COUNTERCLOCKWISE direction.
Thermostat Adjustment
• To INCREASE the water temperature -
WARNING: SHOCK AND BURN HAZARD
To prevent electric shock and burn hazard this
procedure must be performed by a trained and
qualified service technician.
WARNING: SHOCK HAZARD
Disconnect power before attempting any electrical
repairs.
1. With the Thermostat Knob to its maximum
clockwise position, remove the knob and locate the
slotted adjustment screw inside the hollow
thermostat shaft.
2. Using a narrow-bladed screwdriver, engage slotted
adjustment screw and turn it 1/4 turn slowly
counter-clockwise.
3. Allow a few minutes for the temperature to reach
set level. The Heater Light will go ON, indicating the
heating element is activated, wait for it to go OFF,
indicating that the water has reached new set
temperature.
4. Take a temperature reading and repeat if necessary.
6
CCW - Decrease
Temperature
Thermostat Bulb
Cecilware
®
Coupling
Nut
Water Boilers

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Me15enCme15e-nCme10e-n

Table of Contents