Rough-In Drawing

MODEL NO
ME10E-N CME10E-N
ME15E-N CME15E-N
"A"
4.0
MODEL NO
ME10E-N
CME10E-N
ME15E-N
CME15E-N
NOTE:
1. FIELD WIRING MUST BE SUITABLE FOR 75 DEGREES CELSIUS.
2. USE COPPER WIRE ONLY FOR POWER SUPPLY CONNECTION.
3. 120 VOLT UNITS SUPPLIED WITH A GROUNDED 120V-15A LINE CORD AND PLUG.
Water Boilers
GENERAL SPECIFICATIONS
WATER CAP.
(GAL)
10.0
15.0
ME10E-N
OVERFLOW
THERMOMETER
14.0
4.0
ELECTRICAL SPECIFICATIONS
VOLTS
WATTS
120
1,800
240
7,000
208
5,300
240
10,500
208
7,900
Cecilware
DIMENSION "A"
(INCHES)
26.0
30.5
VENT OPENING
POWER
SUPPLY BOX
POWER ON
LIGHT
HEATER ON
LIGHT
POWER
SWITCH
TEMPERATURE
CONTROL
SIDE ACCESS DOOR
(SLIDES UP)
3.4
FIELD WIRING
AMPS
PHASE
15
1
29.2
1
25.5
1
25
3
22
3
®
SHIPPING
WT. (LB)
45
50
WATER INLET
16.0
SIZE
14 AWG
10 AWG
10 AWG
10 AWG
10 AWG