9.1 CP370

Physical specification
Dimensions
Weight
Power specification
Nominal supply voltage
Operating voltage range
Power consumption
Current
Fuse / breakers
Environmental specification
Operating temperature
Storage temperature
Relative humidity
Waterproof rating
CP370 — Sonar specification
Channels
1
Frequency
50 kHz and 200 kHz
Power output
Up to 1 kW RMS (with suitable transducer)
Depth
0.9 m (3 ft) to 1524 m (5,000 ft) (In optimum
conditions and depending on transducer
connected)
Transducer
Transom-mount, in-hull, through-hull
Connections
• 1 x Power connection
• 1 x network connection (RayNet
connector) 10 / 100 Mb/s
• 1 x Transducer connection
Conformance specification
Conformance
50
• Width: 299.4 mm
(11.79 in).
• Height: 204.9 mm
(8.06 in).
• Height (including
connectors): 284.9 mm
(11.2 in).
• Depth: 87.5 mm (3.45 in).
1.435 kg (3.16 lbs)
12 V / 24 V dc
10.8 V to 31.2 V dc
30.6 W (Maximum)
3 A RMS
5 A
–10°C (14°F) to +55°C
(131°F)
–30°C (22°F) to +70°C
(158°F)
95%
IPX6
• EN 60945:2002
• EMC Directive
2004/108/EC
• Australia and New
Zealand: C-Tick,
Compliance Level 2

9.2 CP470

Physical specification
Dimensions
Weight
Power specification
Nominal supply voltage
Operating voltage range
Power consumption
Current
Fuse / breakers
Environmental specification
Operating temperature
Storage temperature
Relative humidity
Waterproof rating
CHIRP Sonar specification
Frequency
25 kHz to 255 kHz
Pulse length
80 ms maximum
Maximum
80 p/s
transmit rate
Power output
2 kW RMS (with suitable transducer)
Depth
0.6 m (2 ft) to 3048 m (10,000ft) (dependent
on connected transducer)
Transducer
Transom-mount, in-hull, through-hull
• 1 x Power connection
Connections
• 1 x Network connection (RayNet
connector) 10 / 100 Mb/s
• 1 x Transducer connection
Conformance specification
Conformance
• Width: 299.4 mm
(11.79 in).
• Height: 204.9 mm
(8.06 in).
• Height (including
connectors): 284.9 mm
(11.2 in).
• Depth: 87.5 mm (3.45 in).
1.539 kg (3.39 lbs)
12 V / 24 V dc
10.8 V to 31.2 V dc
22 W Typical
6 A Peak
5 A
–20°C (–4°F) to +50°C
(122°F)
–30°C (22°F) to +70°C
(158°F)
95%
IPX6
• EN 60945:2002
• EMC Directive
2004/108/EC
• Australia and New
Zealand: C-Tick,
Compliance Level 2
CP370 / CP470