Operational Test; Troubleshooting; Overall Dimensions - Schlage CM5100-FSA-KPI Installation Manual

5100 series.
Table of Contents

Advertisement

OPERATIONAL TEST:

1. Push down and up on inside lever: latch should
retract.
2. Push down and up on outside lever. Lever should
be disengaged from retractor and door should not
unlock.
3. Insert mechanical key into cylinder and turn coun-
terclockwise until it stops. Push down and up on the
outside lever. The door should unlock. (On units with
ATK option you should see the green LED flash on
the keypad/reader when the key is turned.)
4. If the unit has a keypad, enter the factory default
access code:
1 - 3 - 5 - 7 - 9
as soon as "9" is pressed you should hear a quiet
"click" and the green LED should flash green for
about 10 seconds. During this time, push the handle
down - the lock should unlock. After the green LED
stops flashing you should hear another quiet "click"
and the lock should relock. Test the handle again to
verify that it is locked.
Note: Refer to the Programming Guide for information
on entering iButton keys or cards to test them. Note
that some literature may refer to iButtons as "TEKs"
or "TouchEntry Keys".
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any interference received, including any interference that may
cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.

OVERALL DIMENSIONS:

Form 51116-C
CM5100 COMPUTER MANAGED CYLINDRICAL LOCK
HARD-WIRED (FSE/FSA) INSTALLATION MANUAL
PROBLEM:
Inside lever doesn't
retract latch:
No response from key-
pad/reader:
Mechanical key not
working:
Please refer to the programming guide, shipped with
the product, for instructions on manual programming
and creating master programming credentials. If com-
puter programming is required, please refer to the
documentation and help files included with the soft-
ware for more information.
10
TROUBLE SHOOTING:
POSSIBLE CAUSE:
Inside spindle not installed
Wiring harness not plugged
in/external wiring problem.
Electronics problem
(consult tech. support)
Wrong cylinder cam
installed or cam installed in
wrong position. Outside
spindle not installed prop-
erly. Cylinder upside down.
PROGRAMMING:
Customer Service
1-877-671-7011
www.allegion.com/us
© Allegion 2015
Printed in U.S.A.
51116 Rev. 05/15-c