Test Lock Operation; Mechanical Test; Test In Factory Default Mode; Test In Normal Operation Mode - Schlage CO-200 User Manual

Co-series offline locks
Table of Contents

Advertisement

CO-200 Offl ine Lock User Guide
If you encounter problems while performing any of the following tests, review the installation guide
and correct any problems.

Mechanical Test

1. Rotate the inside lever or depress the push bar to open the door. Operation should be smooth,
and the latch should retract.
2. Insert the key into the keyway and rotate the key and the outside lever to open the door.
Operation should be smooth, and the latch should retract. The Schlage button will light solid green
until the key is released and the latch is extended.

Test in Factory Default Mode

1. For locks with a keypad, press any number key. The lock will beep and the Schlage button will
blink red.
2. The Schlage button will blink red twice when a credential is presented and the lock is in factory
default mode, and has no access programming.
3. For locks with keypads, enter the default PIN (13579 and "#") to verify access. The Schlage button
will blink green, a beep will sound, and the door will unlock for the preset relock delay period.
After the relock delay period, the lock will relock and the Schlage button will blink red. If the lever
retracts and holds the latch through the relock delay period, then the Schlage button will light
green until the lever is released.

Test in Normal Operation Mode

1. Present a valid credential. The Schlage button will blink green, a beep will sound and the door
will unlock for the preset lock delay period. The lock will re-lock after the lock delay period and the
Schlage button will then blink red. If the lever retracts and holds the latch through the relock delay
period, then the Schlage button will light green until the lever is released.
2. If an invalid credential is presented, the Schlage button will blink red, a beep will sound and the
door will not unlock.
After credentials have been programmed, present credentials to operate the lock as follows:
Credential Type
Present credential to reader 
Credential
Present credential
+ PIN Credential
to reader 
1 If the PIN is entered incorrectly, press "
2 The default PIN length is six (6) digits. The "#" key must be used as an ENTER key for PINs with fewer than six
digits. PIN length can be confi gured using the SUS, so users do not have to press "#" key.

TEST LOCK OPERATION

NORMAL LOCK OPERATION

Press PIN
" to start over.
*
Action
Green blink and access granted
Within 5 seconds,
1
Press
10
Green blink and
2
access granted