Test Lock Operation; Mechanical Test; Electronic Test - Schlage AD-300 User Manual

Networked hardwired lock
Hide thumbs Also See for AD-300:
Table of Contents

Advertisement

If you encounter problems while performing any of the following tests, review the installation
guide and correct any problems.

Mechanical test

1. Rotate the inside lever. Operation should be smooth and the latch should retract.
2. Insert the key into the keyway and rotate the key or the key and lever to open the door.
Operation should be smooth, and the latch should retract.

Electronic test

Test the AD-300/AD-301 in factory default mode
1. Press any number key. The lock should beep.
2. Press the Schlage button. The keypad should light blue for a few seconds.
3. Enter the default PIN (13579 and "#"). The lock should unlock momentarily and relock
after the default relock delay (3 seconds).
4. Present a credential to the reader. The lock will beep and the Schlage button will blink
red one time. When the lock is in factory default mode and RS485 is not connected, no
credentials are accepted.
Test the AD-300/AD-301 in construction access mode
1. When the master construction credential is presented, the AD-300/AD-301 will beep and
the Schlage button will light green for 20 seconds awaiting the presentation of another
credential to be granted construction user access.
2. When a valid construction access user credential is presented, the lock will unlock for the
re-latch delay period (default three seconds), and the Schlage button will blink green.
When the lock re-locks after the re-latch delay period, the Schlage button will blink red.
3. If an invalid construction access user credential is presented, the lock will beep and the
Schlage button will blink red one time. See Construction access mode on page 6 for
more information.
NOTE: Construction access mode is cancelled when the lock is reset to factory
defaults. When construction access mode is cancelled, the master construction
credential and all other credentials added using the master construction credential
will no longer function.
Test with the AD-300/AD-301 linked to an access control panel
1. Present a valid credential to the AD-300/AD-301. The Schlage button will blink green,
a beep will sound and the door will unlock for the preset lock delay period. The lock will
re-lock after the lock delay period and the Schlage button will then blink red.
2. If an invalid credential is presented, the Schlage button will blink red, a beep will sound
and the door will not unlock. Credential data for all credentials is reported to the ACP.

Test lock operation