Yamaha A5000 Service Manual page 26

Professional sampler
Hide thumbs Also See for A5000:
Table of Contents

Advertisement

A5000/A4000
20
ASSIGNABLE OUT-3
20: ASSIGNABLE OUT-3
Insert the appropriate phone plugs into the ASSIGNABLE OUT-3
terminal. Check the output wave form and the output level of each
output by using an oscilloscope, an AC voltmeter (with JIS-C filter)
and a distortion factor meter.
ASSIGNABLE OUT-3: 1 kHz +/- 1 Hz, sine wave, less than 0.5%
ASSIGNABLE OUT-4: less than -70 dBm (10 k ohm load)
While sounding, the LCD shows as below.
Output on
RESULT OF THE TEST
No display
END OF THE TEST
After pressing the [ENC5] STOP, the test will be finished.
21
ASSIGNABLE OUT-4
21: ASSIGNABLE OUT-4
Insert the appropriate phone plugs into the ASSIGNABLE OUT-4
terminal. Check the output wave form and the output level of each
output by using an oscilloscope, an AC voltmeter (with JIS-C filter)
and a distortion factor meter.
ASSIGNABLE OUT-3: less than -70 dBm (10 k ohm load)
ASSIGNABLE OUT-4: 1 kHz +/- 1 Hz, sine wave, less than 0.5%
While sounding, the LCD shows as below.
Output on
RESULT OF THE TEST
No display
END OF THE TEST
After pressing the [ENC5] STOP, the test will be finished.
22
ASSIGNABLE OUT-5
2 2 : A S S I G N A B L E O U T - 5
Insert the appropriate phone plugs into the ASSIGNABLE OUT-5
terminal. Check the output wave form and the output level of each
output by using an oscilloscope, an AC voltmeter (with JIS-C filter)
and a distortion factor meter.
26
AUTO
distortion
0 +/- 3 dBm (10 k ohm load)
AUTO
distortion
0 +/- 3 dBm (10 k ohm load)
AUTO
ASSIGNABLE OUT-5: 1 kHz +/- 1 Hz, sine wave, less than 0.5%
ASSIGNABLE OUT-6: less than -70 dBm (10 k ohm load)
MANUAL
While sounding, the LCD shows as below.
Output on
RESULT OF THE TEST
No display
END OF THE TEST
After pressing the [ENC5] STOP, the test will be finished.
23
ASSIGNABLE OUT-6
23: ASSIGNABLE OUT-6
Insert the appropriate phone plugs into the ASSIGNABLE OUT-6
terminal. Check the output wave form and the output level of each
output by using an oscilloscope, an AC voltmeter (with JIS-C filter)
and a distortion factor meter.
ASSIGNABLE OUT-5: less than -70 dBm (10 k ohm load)
ASSIGNABLE OUT-6: 1kHz +/- 1Hz, sine wave, less than 0.5%
MANUAL
While sounding, the LCD shows as below.
Output on
RESULT OF THE TEST
No display
END OF THE TEST
After pressing the [ENC5] STOP, the test will be finished.
24
DIGITAL & OPTICAL OUT
2 4 : D I G I TA L & O P T I C A L O U T
Connect the D/A converter in the DIGITAL OUT and OPTICAL
OUT terminals. Check each output wave form and each output level
of each output by using an oscilloscope. Check the sine wave is
output by listening
While sounding, the LCD shows as below.
Output on
MANUAL
RESULT OF THE TEST
No display
END OF THE TEST
After pressing the [ENC5] STOP, the test will be finished.
distortion
0 +/- 3 dBm (10 k ohm load)
AUTO
distortion
less than -70 dBm (10 k ohm load)
AUTO
MANUAL
MANUAL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A4000

Table of Contents