Honeywell SUPER TRADELINE S8610U Installation Instructions Manual page 13

Universal intermittent pilot gas ignition control
Hide thumbs Also See for SUPER TRADELINE S8610U:
Table of Contents

Advertisement

MV
PILOT
COM
1ST
2ND
OPERATOR
OPERATOR
DUAL VALVE COMBINATION
GAS CONTROL
PILOT
BURNER/
IGNITER
PILOT
GAS SUPPLY
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
2
ALTERNATE LIMIT CONTROLLER LOCATION.
3
MAXIMUM CABLE LENGTH 3 FT. [0.9 M].
CONTROLS IN 24V CIRCUIT MUST NOT BE IN GROUND LEG TO TRANSFORMER.
4
LEAVE VENT DAMPER PLUG (P1) UNCONNECTED.
5
FOR SINGLE ROD APPLICATIONS: CONNECT JUMPER WIRE TO THE REMOTE SENSE
6
CONNECTOR.
FOR TWO ROD APPLICATIONS: REMOVE JUMPER WIRE BY CUTTING IT AS CLOSE AS
POSSIBLE TO THE BASE OF THE MODULE, DISCARD CLIPPED WIRE, AND FIRMLY ATTACH
THE SENSOR WIRE FROM THE IGNITER/SENSOR ASSEMBLY TO THE REMOTE SENSE
CONNECTOR.
Fig. 4. S8610U connections in a heating system with an atmospheric burner and no vent damper.
S8610U UNIVERSAL INTERMITTENT PILOT GAS IGNITION CONTROL
S8610U
GND
MV/
24V
PV
PV
(BRN)
GND 24V TH-W
MAIN
VALVE
2
4
PILOT
BURNER
GROUND
5
ENVIRA
REMOTE
COM ™
P1
SENSE
SPARK
6
JUMPER
WIRE
THERMOSTAT
LIMIT
CONTROLLER
1
L1 (HOT)
L2
JUMPER WIRE
CLIPPED CLOSE
TO BOARD
SENSOR WIRE
FROM IGNITER/
SENSOR
13
3
TWO ROD
REMOTE
6
SENSE
M23617
69-1955