Component
Dense intermix drive tray
Required height
Component
CBLM
SFF
LFF
DBF
Dense intermix drive tray
Cache specifications
Item
Capacity (GB)
NAS module Cache Capacity
Control method
Battery backup
Backup duration
Data in the cache memory is preserved against power failures. If a power
outage occurs, data in cache memory is written to drives.
When the storage system enters Cache Backup mode, the amber WARNING
LED goes on to when the system starts. This warning indicates that the
battery charge has dropped significantly and the remaining battery capacity
is not sufficient; the storage system will continue operating with the Write
Cache function disabled.
When the battery is charged, the warning indication disappears, and the
storage system continues the operation in the Write Cache function.
Mechanical specifications for VSP G400, G600
Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide
Specification
Approx. 198.41 pounds (90 kg)
Specification
4 U
2 U
2 U
2 U
4 U
If a drive is inserted into a slot of a dense
intermix drive tray when the installed number of
drives exceeds 240 slots per path, the drive is
blocked.
Specification
VSP G400: 128
VSP G600: 256
DDR3 DIMM 8GB x 12 [Slot]
Note:
All 12 slots must be fully installed with
DIMMs.
Each DIMM is replaceable when they fail.
The DIMM is not common and cannot be
used with DKC DIMM.
Read LRU, Write after
Provided
Unrestricted (saving to a nonvolatile memory)