The CDMAEZ can be connected to an alarm system using up to four inputs on the CDMAEZ. Each of these inputs can be set up to send a selected signal to the monitoring station. Contact ID, SIA, Modem IIe/IIIa and 4/2 (:20 PPS) formats are supported.
Before beginning installation: If you are not yet an Uplink dealer, register by visiting www.uplink.com and click on the “new dealer account” tab. Step 1. Activate the system. The Uplink CDMAEZ operates “out of the box” with most commercial panels. No additional programming or equipment is required. To activate with default functions, go to www.uplink.com, or use the Uplink Installer App, or call...
Page 8
Step 5. Disconnect the unit from the power supply before wiring. The standard configuration for the Uplink CDMAEZ is to leave DIP switches S3 and S4 set to “OFF” (Input 1 triggered by 9V DC to 12V DC or an open collector). For detailed wiring instructions and alternative configurations, see pages 8-9.
Page 9
Note: The DIP switches are only read immediately after the unit is powered up. Always cycle the unit’s power after making changes to the DIP switch settings. FIGURE 2: MODEL CDMAEZ DIP Switch Status LEDs Terminal Block...
This is an option on most panels. Input 4 (DIP switch S8 ON) A trigger of INPUT 4 from high-to-low and back-to- high causes the CDMAEZ to reset. The high-to-low-to-high must be held for at-least 100 msec. (UNIT WIRING continued next page)
CDMA Universal ® CDMAEZ Alarm Communicator UNIT WIRING (cont.) *Inputs 2, 3, and 4 (and Input 1 if Standard Type) FIGURE 4: Wiring example for voltage trip Voltage Trip - Inputs 2, 3, and 4 (and 1 if set for standard input) can be tripped by applying 12 V to the + input and 0 V to the - input.
CDMA Universal ® CDMAEZ Alarm Communicator Power Supply - The customer-supplied 12 V DC power supply/battery charger should be capbable of supplying 500 mA peak for brief high current demands of the radio during transmission. ANTENNA SPECIFICATION The following types of antennas should be used with this unit: Antenna type: External Dual Band ¼...
CDMA Universal ® CDMAEZ Alarm Communicator FCC & INDUSTRY CANADA REGULATORY COMPLIANCE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference; and (2) this device must accept any interference received, including interference that may cause undesired operation.
CDMA Universal ® CDMAEZ Alarm Communicator FCC RF EXPOSURE INFORMATION In August 1996 the Federal Communications Commission (FCC) of the United States with its action in Report and Order FCC 96-326 adopted an updated safety standard for human exposure to radio frequency electromagnetic energy emitted by FCC regulated transmitters.