Removal
WARNING
Before disconnecting or performing any work
on the hydraulic system, all pressure in the
system must be relieved. See Relieving Hy-
draulic System Pressure in the General Infor-
mation section.
1. Remove control valve from the frame using Figures
58 and 59 as guides.
2. If hydraulic fittings are to be removed from control
valve, mark fitting orientation to allow correct assembly.
Installation
1. If hydraulic fittings were removed, install fittings to
control valve using marks made during the removal pro-
cess to properly orientate fittings.
2. Install control valve to the frame using Figures 58
and 59 as guides.
Reelmaster 3100−D
2
1. Spool valve
2. Magnet support bracket
Page 4 − 91
1
3
Figure 59
3. Flange head screws
4. Frame
Hydraulic System
4