Hisense AUD-18UX4SGKL Service Manual page 64

Dc inverter air conditioner
Hide thumbs Also See for AUD-18UX4SGKL:
Table of Contents

Advertisement

6
.
C
O
N
T
R
O
L
M
6
.
C
O
N
T
R
O
L
M
Outdoor mode control ( AUW-18U4SG 、 AUW-24U4SZ 、 AUW-36U4SA 、 AUW-48U6SP 、
6-2
AUW-60U6SP、AUW-18U4SZ1、AUW-24U4SA1、AUW-36U4SA1)
Summarization
1.1This direction applies to multi-type and DC variable frequency air conditioner
Performance index (AUW-18U4SG 、 AUW-24U4SZ、 AUW-36U4SA、 AUW-18U4SZ1、 AUW-24U4SA1、
AUW-36U4SA1)
1. Voltage scale: 176V~253V,50Hz
2. Storage temperature scale: -40℃~85℃
3. Storage humidity scale: PH30%~PH95%
4. Working temperature:-20℃~85℃
5. accuracy for temperature control: ±0.5℃
1.2 This direction applies to multi-type and DC variable frequency air conditioner
Performance index(AUW-48U6SP、AUW-60U6SP)
1. Voltage scale: 305V~438V,50Hz
2. Storage temperature scale: -40℃~85℃
3. Storage humidity scale: PH30%~PH95%
4. Working temperature:-20℃~85℃
5. accuracy for temperature control: ±0.5℃
2.Control function
2.1Cooling Anti-freeze Protection