2
.
S
P
E
C
I
F
I
C
A
T
2
.
S
P
E
C
I
F
I
C
A
T
Model
Power supply
Cooling
Capacity
Heating
Dehumidification
Cooling
Rated input
Heating
Cooling
Rated Current
Heating
Cooling
Max. input
Heating
Cooling
Max.Current
Heating
SEER/SCOP
Compressor
Winding resistance
Indoor
Fan motor
Outdoor
Fan
Indoor
Fan speed
Outdoor
Indoor
Air circulation
Outdoor
Static Pressure(*Default Setting)
Operating control
Indoor
Dimensions
Outdoor
Panel
Packing
Indoor
I
O
N
S
I
O
N
S
Ph-V-Hz
kW
Btu/h
kW
Btu/h
L/h
kW
kW
A
A
kW
kW
A
A
Model
Type
Ω
Brand
Model
Winding
resistance
(at20℃)
Model
Winding
resistance
(at20℃)
type
Speed
r.p.m
Hi/Med/Low
type
r.p.m
Speed
r.p.m
Hi/Med/Low
Hi/Med/Low
m³/h
Hi/Med/Low
m³/h
Pa
L×W×H
mm
L×W×H
mm
L×W×H
mm
L×W×H
mm
12
AUC-18UR4SZAA1
1N,220V~240V/50Hz
5(1.2-6.5)
17,100(4,100-22,200)
23,900(7,500-27,300)
5.6(1.8-7.2)
19,100(6,100-24,600)
28,000(8,500-34,100)
——
1.49(0.40~2.25)
1.75(0.38~2.15)
6.6
7.8
2.5
2.5
12
12
5.6/3.8
DA131S1B-28FZ
2-cylinder type rotary
0.55(20℃)
GMCC
EHDS50AQ
/
ARW4401QH
SIC-71FW-D8121-1
/
980/840/720
0-810
--
--
0
Wireless Remote control(J1-05)
650×570×270
900×300×640
650×650×30
770×750×310
AUC-24UR4SAEA1
AUC-36UR4SAEA1
7.0(2.2-8.0)
9.5(3.6~10.5)
32,400(12,300-35,800)
8.2(2.5-10)
11.0(3.05~13.8)
37,500(10,400-47,100)
——
2.3(0.40~3.6)
2.73(0.38~3.6)
3.10(0.38~4.2)
10.1
12.2
3.6
3.6
15.5
15.5
5.6/3.8
DA230S2C-31MT
DA250S2C-30MT
0.73 (at20℃)
GMCC
ARW5901QH
/
SIC-71FW-D8121-1
/
centrifugal fan
440/380/370
tube-axial
0-810
--
--
0
840×840×248
950×340×840
950×950×37
930×930×290
——
3.07(0.4~4.2)
13.4
13.5
4.25
4.25
20
20
5.1/3.8
055(20℃)
GMCC
EHDS50AQ
/
/
630/520/460
0-810
--
--
0
840×840×248
950×340×840
950×950×37
930×930×290