1
E 01
User Fault
2
E02
Battery Fault
3
E03
Left Motor Fault
4
E04
Right Motor Fault
Part No 1160845
SECTION 3—SAFETY INSPECTION/TROUBLESHOOTING
00
Stall Timeout or user error.
00
Recharge batteries or replace.
00
Left Motor Short Circuit
01
Left Motor Open Circuit
02
Left Motor Connection Fault
B-
03
Motor Terminal Connected
to B+
04
Left Motor Voltage Fault
05
Left Motor Bridge Fault
06
Too Many Hardware Current
Limit Events
07
Current Offset Out of Range
08
Hardware Current Limit Fault
00
Right Motor Short Circuit
01
Right Motor Open Circuit
02
Right Motor Connection Fault
B-
03
Motor Terminal Connected
to B+
04
Right Motor Voltage Fault
05
Right Motor Bridge Fault
06
Too Many Hardware Cur-
rent Limit Events
07
Current Offset Out of Range
08
Hardware Current Limit Fault
21
Release joystick to neutral and try again.
Check the batteries and cable. Try
charging the batteries. Batteries may
require replacing.
Check the left motor, connections and
motor cable.
Check the right motor, connections and
motor cable.