Indesit ISL70CNL Service Manual page 47

Yate production dryers
Table of Contents

Advertisement

ARISTON
Pump not wired
Valid only for condenser models.
STATE
No pump action
ARISTON
Display board does not manage to communicate with
STATE
No communication be-
tween display board
and main board.
Service Manual
Yate Production Dryers
FAULT 11
CORRECTIVE ACTIONS
Check resistance continuity of the
pump.
Check state of the connectors.
Check continuity and state of the
wiring.
FAULT 12
CORRECTIVE ACTIONS
Unplug the machine, wait for 2 min-
utes, switch it ON and try it again.
Check state of the connectors.
Check continuity and state of the
wiring.
If the wires and connectors are ok.
INDESIT
INTERVENTION TO BE PERFORMED
f not OK, replace the pump.
- Clean and refi t.
- Change the wiring.
- Replace the main board.
INDESIT
INTERVENTION TO BE PERFORMED
- f the machine starts, ok.
- Clean and refi t.
- Change the wiring.
- Replace the main board.
- Replace the display board.
Edition
2006.09.21