Indesit ISL70CNL Service Manual page 45

Yate production dryers
Table of Contents

Advertisement

ARISTON
STATE
Front NTC open or
short circuit.
FAULT 04 – PUMP TRIAC WELDED CLOSED
ARISTON
Valid only for condenser models
STATE
Pump is working when
it should not.
ARISTON
No feedback from pump
Valid only for condenser models.
STATE
No pump action
Service Manual
Yate Production Dryers
FAULT 03 – FRONT NTC FAULT
CORRECTIVE ACTIONS
Check resistance value of the NTC. It
should be about 500 kOhms in room
temperature.
Check state of the connectors.
Check continuity and state of the
wiring.
CORRECTIVE ACTIONS
FAULT 05
CORRECTIVE ACTIONS
Check resistance continuity of the
pump.
Check state of the connectors.
Check continuity and state of the wiring.
Check that there is voltage (220V)
on the pins 1 and 2 and 3 on the
connector J5.
INDESIT
INTERVENTION TO BE PERFORMED
- Replace the NTC.
- Clean and refi t the connectors.
- Change the wiring.
- Replace the main board.
INDESIT
INTERVENTION TO BE PERFORMED
- Triac in short circuit; replace the main board.
INDESIT
INTERVENTION TO BE PERFORMED
- If not ok, replace the pump.
- Clean and refi t the connectors.
- If not ok, replace the wiring.
- If not ok, (triac of the pump does not close),
replace the main board.
Edition
2006.09.21
E
Language
English
n
45