Indesit ISL70CNL Service Manual

Yate production dryers

Advertisement

SERVICE MANUAL
YATE PRODUCTION DRYERS
All parts of this document are the property of Indesit Company S.p.A.
All rights reserved. This document and the information it contains are supplied with no acceptance of
liability deriving from possible errors or omissions. Furthermore, no part may be reproduced, used or
disclosed except where authorized in writing or in accordance with a contractual clause.
Service Manual
Yate Production Dryers
Edition
2006.09.21
E
Language
English
n


Advertisement

Table of Contents
loading

Summary of Contents for Indesit ISL70CNL

  • Page 1 SERVICE MANUAL YATE PRODUCTION DRYERS All parts of this document are the property of Indesit Company S.p.A. All rights reserved. This document and the information it contains are supplied with no acceptance of liability deriving from possible errors or omissions. Furthermore, no part may be reproduced, used or disclosed except where authorized in writing or in accordance with a contractual clause.
  • Page 2 CONTENTS Of ThE MANUAL: NOTE fOR SERVICE TEChNICIAN. This manual is a support document for technical personnel. It contains a description of the various product types and their operating principle, and provides indications on serviceability. Service technicians should always consult the specific model on (www.servicenet.indesitcompany.com) to find data and updates of wiring diagrams, technical bul- letins and spare parts...
  • Page 3: Table Of Contents

    3 COMPONENTS 3.1 ELECTRONIC CONDENSER AND VENTED DRYERS 3.2 ELECTROMEChANICAL CONDENSER AND VENTED DRYERS 4 wIRINg DIAgRAMS 4.1 INDESIT ELECTROMEChANICAL VENTED MODELS 4.2 ARISTON ELECTROMEChANICAL VENTED MODELS 4.3 VENTED MODELS wITh SENSINg bRUSh 4.4 VENTED MODELS wITh SENSINg STRIP 4.5 CONDENSER MODELS wITh SENSINg bRUSh 4.6 CONDENSER MODELS wITh SENSINg STRIP...
  • Page 4: Product Legend

    C EX A = Ariston S = Scirocco Project L= LED 7 = 7 kg 0 = second digit V = Vented Market I = Indesit D= Display 6 = 6 kg indicates a possible 0 =Electromechnical update C = Condenser 1.2.
  • Page 5: Product Interface

    1.3. PRODUCT INTERfACES: 1.3.1 DISPLAY INTERfACE Legend: 1. DRYINg gUIDE 5. ON/Off indicator Led 2. OPTION buttons 6. PROgRAMME SELECTION buttons 3. ON/Off button 7. START/CANCEL button 4. DISPLAY The START/CANCEL button starts a selected The ON/Off indicator confirms that the dryer programme.
  • Page 6 Press the door to release the latch, open the If Post Care has been selected and the laundry is dryer, then proceed to check the position and not removed immediately, the dryer will continue cleanliness of the filter and make certain that to operate intermittently for 10 hours, or until such the water tray is empty and correctly in place time as the door is opened.
  • Page 7 Legend: 1. DRYINg gUIDE 5. ON/Off indicator Led indicator Led 9. CLEAN fILTER 2. OPTION buttons 6. PROgRAMME selector knob PROgRESS indicator 10. PROgRAMME 3. OPTION indicator Leds 7. START/CANCEL button Leds 4. ON/Off button indicator Led 8. EMPTY wATER The START/CANCEL button starts a selected the dryer must be in operation (see Controls).
  • Page 8 1.3.3 MEChANICAL INTERfACE Legend: 4. ON/Off button 7. PROgRAMME SELECTOR knob 1. DRYINg gUIDE indicator Led 5. ON indicator Led 8. EMPTY wATER 2. hEAT buttons 6. DELAYED START knob 3. bUZZER buttons The selected drying programme is initiated by pres- The TIMER knob is used to set the interval of time sing the START button (see Start and programmes that must elapse before the start of a delayed drying...
  • Page 9: Led Interface

    1.4 TEChNICAL DATA - CONDENSER/VENTED DRYERS MODELS ISL70CNL ASD70CEX AS60VEX Electronic control and LED Electronic control and di- Rx/Lx rotation, End-of-pro- fEATURES interface splay interface gramme alarm ENERgY CLASS 72 dBA 72 dBA 72 dBA NOISE LEVEL H 850 mm...
  • Page 10: Operating Logic

    2. OPERATINg LOgIC: 2.1 CONDENSER DRYINg CYCLE AND CIRCULATION Of EXTERNAL AIR - STEAM - wATER Filter Condenser steam inlet Condenser Front fan Tray collecting water produced by condensation of steam Heating elements Holes admitting hot air to drum Pump and hoses Motor 10 Rear fan The motor sets the drum in rotation, as well as driving...
  • Page 11 The steam passes through a filter located in the bottom part of the door seal and is channelled into the condenser. Rear part of drum Steam filter Condenser 1 Steam inlet from filter 2 Condensing chamber 3 Fan-assisted cold air inlet The steam condenses as a result of the drop in temperature;...
  • Page 12 7 Pump 9 Water inlet, from pump 8 Water tray handle 10 Assembly The pump is always on, and in the event that it should seize, the rising water level in the reservoir will cause a float to trip a microswitch, generating a FAULT signal used by the mainboard to deactivate the heating elements.
  • Page 13 Safety in respect of thermal overloads and electrical faults is guaranteed by two thermostats mounted on the heating element bracket (one self-resetting, which cycles on and off to limit the temperature in the drum, the other a one-shot overall safety device). 14 One-shot thermostat 15 Cold air inlet.
  • Page 14: Vented Drying Cycle

    2.2 VENTED DRYINg CYCLE AND CIRCULATION Of AIR - STEAM - wATER (ELECTROMEChANICAL) Filter and steam outlet from drum Steam venting duct Cold air inlet Holes admitting hot air to drum at rear Heating elements Vent outlet and connection for external duct Motor Fan blowing cold air onto heating elements Fan and heater guard...
  • Page 15 (one resettable and cycling on/off to keep the air temperature within 120 °C, the other a one-shot type that opens irreversibly when exposed to a temperature of 150 °C). Depending on the type of machine (Ariston or Indesit), drying temperatures are governed by thermostats positioned adjacent to the hot air (steam) duct.
  • Page 16: Electronic Control Logic

    2.3 ELECTRONIC CONTROL LOgIC Estimate of programme duration on the basis of communication between the two NTC sensors and the conductivity sensor. The method for calculating the duration of programmes is as follows: • Each drying cycle includes a procedure, active for the first 10’, in which the controller establishes the type of load, and in particular the moisture content.
  • Page 17 Air temperatures for single programmes • Indesit electromechanical condenser dryers: front thermostat operates at 78 °C. • Indesit electromechanical vented dryers: front thermostat operates at 58 °C • Electromechanical vented dryers (Ariston): operating temperatures of the front thermostats are 55 °C for full load and 60 °C for half load.
  • Page 18: Programmes - Condenser Dryer With Display

    Start and Programmes 2.5 PROgRAMMES - CONDENSER DRYER wITh DISPLAY Programmes Programmes ! If the On/Off indicator is not alight: Press the ON/OFF button and select the programme. ! If the On/Off light is not lit; Press the ON/OFF button and then select programme.
  • Page 19 Controls ! warning. If after pressing the START button, the position of the programme knob is changed, the new position will NOT change the selected programme. ! ON/Off button : pressing this button will stop the programme. Pressing a second time, the programme will resume.
  • Page 20 The time remaining until the end of the process, including the cooling step, is displayed in hours and minutes and counted down minute by minute. The display shows HIGH temperature 2:20 or LOW temperature 2:20. When timer delayed programmes are selected, the time displayed during the cycle is the time remaining at that particular moment.
  • Page 21: Programmes - Condenser Dryer With Leds

    Start and Programmes 2.6 PROgRAMMES - CONDENSER DRYER wITh LEDS Programmes Programmes ! If the On/Off light is not lit; Press the ON/OFF button ! If the On/Off indicator is not alight: Press the ON/Off button and then select programme. and select the programme.
  • Page 22 OPTION buttons / indicators These buttons are used to personalize the selected programme on the basis of individual needs and prefe- rences. Before any option can be selected, a programme must be selected with the knob. Not all the options are available for all programmes (see Start and programmes section).
  • Page 23 (If the dryer is connected to a drain line, this indicator can be ignored as there is no need to empty the condensate tray). When this indicator is alight (permanently) it reminds the user to empty the tray. If the tray should fill up during the course of a programme, the heater switches off and the dryer activates a Cooling step.
  • Page 24: Programmes - Electromechanical Vented Dryer

    Start and Programmes 2.7 PROgRAMMES - ELECTROMEChANICAL VENTED DRYERS Programmes Programmes Note: Programme What it does... How to set it... Automatic 1. Select HIGH HEAT by pressing ! If you select LOW HEAT, Dries completely: Drying this programme will not dry the HEAT button.
  • Page 25: Components

    3. COMPONENTS: 3.1 ELECTRONIC CONDENSER AND VENTED DRYERS Conductivity sensor Measures the moisture content of the fabrics, and NEw conductivity sensor interacts with the two NTC sensors to compute the OLD conductivity sensor time remaining. Readings occur every 40” approx. filter Rear fan, condenser dryer Traps any threads and fluff shed by the tumbled...
  • Page 26: Heater Unit

    Mainboard Condenser The mainboard is located in the bottom front part, on the right; it includes a serial port for connection of the hardware key. The board can programmed if replaced, or if the EEPROM file suffers damage, or when a new version becomes available.
  • Page 27 Drum bearings (front) front NTC sensor The front NTC sensor is mounted in the top part of the front air duct. This sensor is used by the electro- nics to control the drying temperature; as soon as the air reaches a given set point, one heating element front of seal is switched off.
  • Page 28: Door Switch

    55 °C. The third automatic programme is controlled by the timer • Indesit vented dryer - This has just one thermo- stat that opens at 58 °C to deactivate one heating element, then closes to reactivate the element...
  • Page 29: Float Switch And Drain Pump

    float switch and drain pump Motor The motor is a two pole type running at 2800 rpm. Protection is guaranteed by a bimetal thermal overload cutout that resets automatically, and may disconnect the electrical power input to the windings. A start capacitor rated 7 µF is installed alongside. Mainboard (LED or LCD) the mainboard is located behind the control panel.
  • Page 30: Electromechanical Condenser And Vented Dryers

    This feature is a standard safety requirement on dryers with appreciably large doors. • Indesit vented: 160’ including 12’ to cool the fa- brics The options on the power PCB allow for the use of a low voltage buzzer and/or LEDs. Certain earlier •...
  • Page 31 Drum The ECO thermostats are mounted in the front part of the air duct. • In ARISTON dryers and in certain INDESIT mo- dels, the settings are: THE drum has a back plate pierced with holes to 55 °C full load admit the flow of air warmed by the heating elements;...
  • Page 32: Wiring Diagrams

    4. wIRINg DIAgRAMS: 4.1 INDESIT ELECTROMEChANICAL VENTED MODELS SwITCh RATINgS REVERSINg TIMERS Type CONTACT / RATINg COMPONENT MAX. TERMINAL SwITChED CURRENT PEAPSA 2 - 1 Invensys ZBN 2 - 1 16 (4) A MOTOR & 12 A HEATER Invensys EC...
  • Page 33 Service Manual Edition Language Yate Production Dryers 2006.09.21 English...
  • Page 34: Ariston Electromechanical Vented Models

    4.2 ARISTON ELECTROMEChANICAL VENTED MODELS SWITCH RATINGS TIMER CONTACT / TERMINAL RATING COMPONENT MAX. SWITCHED CURRENT SWITCH RATINGS TIMER Invensys EC Elbi 5000 C3 – C2 C3 –C4 16(4)A TIMER MOTOR <1A CONTACT / TERMINAL RATING COMPONENT MAX. SWITCHED CURRENT C3 –...
  • Page 35 Service Manual Edition Language Yate Production Dryers 2006.09.21 English...
  • Page 36: Vented Models With Sensing Brush

    4.3 VENTED MODELS wITh SENSINg bRUSh Legend: User interface PCb Upper and lower heating elements front NTC sensor NTC sensor Capacitor Door switch Spade terminal Connection to a.c. supply with suppressor Motor with overload cutout Sensing brush One-shot thermostat Drum assembly Resettable thermostat Service Manual Edition...
  • Page 37: Vented Models With Sensing Strip

    4.4 VENTED MODELS wITh SENSINg STRIP Legend: A User interface PCb h Upper and lower heating elements b front NTC sensor Door switch C Capacitor Connection to a.c. supply with suppres- D Spade terminal E Motor with overload cutout K Sensing strip f One-shot thermostat L Drum assembly g NTC sensor...
  • Page 38: Condenser Models With Sensing Brush

    4.5 CONDENSER MODELS wITh SENSINg bRUSh Legend: A User interface PCb Upper and lower heating elements b front NTC sensor K NTC sensor C float switch L Connection to a.c. supply with sup- D Pump pressor E Capacitor M Door switch f Motor with overload cutout N Sensing brush g Spade terminal...
  • Page 39: Condenser Models With Sensing Strip

    4.6 CONDENSER MODELS wITh SENSINg STRIP Legend: A User interface PCb Upper and lower heating elements b front NTC sensor K Door switch C float switch L Connection to a.c. supply with sup- D Pump pressor E Capacitor M Sensing strip f Motor with overload cutout N Drum assembly g Spade terminal...
  • Page 40: Serviceability

    5. SERVICEAbILITY 5.1. DEMO MODE Not available for tumble dryers 5.2. AUTOTEST AND fUNCTIONS SEqUENCE Requires hardware key to activate (part number: C00095669). New model Old model Service Manual Edition Language Yate Production Dryers 2006.09.21 English...
  • Page 41: Autotest With Led Interface

    5.2. AUTOTEST AND fUNCTIONS SEqUENCE 5.2.1 AUTOTEST wITh LED INTERfACE The test programme requires the use of the hardware key and test fuse, which has a resistance of approx 270k between the two magnets. The fuse is installed between the conductivity sensor and the drum. To set up the test programme, close the door and press the button on the HW key.
  • Page 42 NOTE: when a fault occurs, the door interlock Led blinks rapidly (frequency > 1 hz, i.e. several times per second) [INDESIT machines] when a fault occurs, the On/Off Led blinks rapidly (frequency > 1 hz, i.e. several times per second)
  • Page 43 5.3. fAULT INDICATION wITh LED INTERfACES With the LED interface, the Leds that indicate the fault remain permanently alight, whereas the progress indicator Leds blink Indesit control panel Ariston control panel FUNCTION BUTTONS PROG LEDs FUNCTION BUTTONS DOOR INTERLOCK (L1)
  • Page 44 5.4. fAULTS AND TROUbLEShOOTINg FAULT 01 - MOTOR FAULT ARISTON INDESIT STATE CORRECTIVE ACTIONS INTERVENTION TO BE PERFORMED Check that moisture has not made a - Dry and refi t the connector. Motor functions when short circuit on connector J3.
  • Page 45 FAULT 03 – FRONT NTC FAULT ARISTON INDESIT STATE CORRECTIVE ACTIONS INTERVENTION TO BE PERFORMED Check resistance value of the NTC. It - Replace the NTC. Front NTC open or should be about 500 kOhms in room short circuit. temperature.
  • Page 46 FAULT 08 ARISTON INDESIT Lower heater relay welded closed. STATE CORRECTIVE ACTIONS INTERVENTION TO BE PERFORMED Check that there arrives always (even - If yes, relay is welded; replace the main Lower resistance is when it should not) 220V on the pins board.
  • Page 47 FAULT 11 ARISTON INDESIT Pump not wired Valid only for condenser models. STATE CORRECTIVE ACTIONS INTERVENTION TO BE PERFORMED Check resistance continuity of the f not OK, replace the pump. No pump action pump. Check state of the connectors. - Clean and refi t.
  • Page 48 FAULT 13 ARISTON INDESIT Rear NTC fault STATE CORRECTIVE ACTIONS INTERVENTION TO BE PERFORMED Check resistance value of the NTC. It - Replace the NTC. Resistance NTC open should be about 500 kOhms in room or short circuit. temperature. - Clean and refi t.
  • Page 49 Noise CORRECTIVE ACTIONS INTERVENTION TO BE PERFORMED Check the fan. - V&C. Scraps on inner rear panel (S/N is before the 29th September 2004 for C, the 29th of November 2004 for V). The rear impellors are distorted: to substitute with C00113867 (condenser) and with C00112153 Inner &...
  • Page 50 From the 8th of June on. Part codes C00113038 & C00112158. Drum off front bearings. - V. Front support bracket kit (Indesit models). Introduced October 2004 (DC34). Part code C00116349 Bracket (RH) & C00116350 Bracket (LH).
  • Page 51 No drum action CORRECTIVE ACTIONS INTERVENTION TO BE PERFORMED Check the belt. - C. Adrift from the jockey pulley or broken caused by the jockey wheel movement (S/N before the 19th of October 2004): improve the bearing & plastic moulding fi...
  • Page 52 INTERVENTION TO BE PERFORMED S/N is before the 18th of August 2005. - C. Indesit door assembly modified to secure door liner hinge blocks improved fit of outer door panel: part code C00114678. Door not closing / Door catch broken...
  • Page 53 Door seal distortion (Indesit, Creda) CORRECTIVE ACTIONS INTERVENTION TO BE PERFORMED S/N is before the 19th of January 2005. - V. Circular rib added to door seal to prevent distortion. Part code C00112143 Door Seal. Pump cover becoming adrift CORRECTIVE ACTIONS INTERVENTION TO BE PERFORMED S/N is before the 26th of January 2005.
  • Page 54 Side panel alignment CORRECTIVE ACTIONS INTERVENTION TO BE PERFORMED S/N is before the 22th of August 2005. - V. Side panel corner improvement, corner is now rounded instead of a sharp peak. Side panel part code C00112184. Drum lifter security CORRECTIVE ACTIONS INTERVENTION TO BE PERFORMED S/N is before the 1st of August 2005.
  • Page 55: Condenser Dryer Components

    5.5. DISASSEMbLY: 5.5.1 ELECTRONIC CONDENSER DRYER COMPONENTS: Top: 1. Remove the 2 screws securing the top to the rear 2. Slide the top back and lift. panel. Side panels: 1. Remove the top. 3. Slide the panel back to free it from the lugs at the bottom 2.
  • Page 56: Control Panel

    Control panel: 1. Remove the top. Remove 2 screws securing the 2. Remove the water tray. control panel to the side panels Remove 2 screws on the left of the control panel, securing it to the tray holder Remove 1 screw on the right, securing the control panel to the side restraint 3.
  • Page 57 Power PCb: 2. Remove the Rx panel 1. Remove the top Detach the cowl from the front fan so that the PCB Lower the plinth, and remove. is able to pass Remove the 2 fixing screws at the front belt: 1.
  • Page 58 4. Remove the guard from the heater unit 6. Remove the 4 hex bolts behind the rear fan, which secure the motor to the base; This will slacken the 5. Detach the rear fan drive belt. 7. Remove the rear bearing 8.
  • Page 59: Front Panel

    front panel 1. Remove the top and control panel 3. Remove the duct from the socket at the bottom 2. Undo the screws retaining the air duct (this operation is made easier by laying the ma- chine on its back) 4.
  • Page 60: Air Duct

    Air duct 1. Remove the top, control panel, side panels, front panel and motor 2. Raise the drum and remove the air duct front bearings 1. Detach the air duct 2. Replace the 4 bearings Rear bearing 1. Remove the guard of the rear bearing 2.
  • Page 61 Pump switch and float 1. Remove the Lx side panel 2. Release the two clips securing the cover of the 3. Release the reservoir from the base (Rx and reservoir to the base 4. Replace the pump / switch or float heater unit - safety thermostats - NTC sensors 1.
  • Page 62: Drum Assembly

    Motor 1. Detach the Rx SIDE PANEL 2. Detach the front fans, removing the relative guard (the mainboard must be removed) 4. Release the motor from the panel, removing the 4 bolts 3. Detach the rear fan 5. Lift the motor from the base, slip off the belt and remove the tension idler Drum assembly 3.
  • Page 63: Vented Dryer Components

    5.5.2 DISASSEMbLY Of VENTED DRYER COMPONENTS a) Removal of timer, programmer - door interlock relay and switches 1. Detach the control panel and remove the two 3. Detach the two timers, undoing the screws that screws securing the angle bracket secure them to the bracket 2.
  • Page 64 c) Removal of front panel and air duct d) Removal of motor 1. The following steps will be made easier by laying 1. Detach the right hand side panel the machine on its back 2. Remove the rear guard of the heater unit and 2.
  • Page 65 e) Removal of belt 1. Detach the two side panels 2. Detach the front panel and air duct 3. Detach the motor 4. Release the motor by undoing the two front bolts and the rear bolt securing it to the mounting 4.
  • Page 66 f) Removal of drum h) Removal of drum reversing timer 1. Complete all steps necessary in order to remove the belt 2. Remove the rear belt and separate the drum shaft from the rear panel; the drum can now be removed from the casing 1.
  • Page 67: Exploded Drawings

    6. EXPLODED DRAwINgS AS60VEX Ref. Description Ref. Description LVB CONNECTION KIT - VENTED DRYERS BUZZER SWITCH AS60VEX CONTROL PANEL POTENTIOMETER AS60VEX TIMER KNOB AS60VEX TOP AS60VEX DELAY KNOB AS60VEX PCB AS60VEX BUTTON AS60VEX START BUTTON HEAT SWITCH AS60VEX BUTTON START SWITCH TIMER MOUNTING PLATE TIMER AS60VEX LIGHT GUIDE...
  • Page 68 AS60VEX Ref. Description Ref. Description AS60VEX PLINTH MICROSWITCH DELAY MICROSWITCH DELAY AS60VEX FILTER FRONT THERMOSTAT AS60VEX DOOR FRAME DOOR SURROUND TUBE, AIR DUCT FRONT SEAL, DRUM AS60VEX DOOR GLASS FRONT PANEL, WHITE DOOR GLASS SEAL AS60VEX DOOR HINGE FRONT PANEL, WHITE THERMOSTAT (WHITE LIGHT) AS60VEX DOOR HANDLE DOOR CATCH...
  • Page 69 AS60VEX Ref. Description Ref. Description BASE FLANGE, VENTING HOSE BASE (WITH FEET) FLANGE, VENTING HOSE WHEEL PIVOT THERMOSTAT KIT (ONE SHOT+CYCLING) WHEEL CABLE GLAND DRYER FOOT POWER CABLE AS60VEX MOTOR, TYPE 358 NOISE FILTER A35VEX60 CAPACITOR KIT SCREW INNER FAN AS60VEX SIDE PANEL OUTER FAN (6BLD 5HLE) 6X3/8 SCREW...
  • Page 70: Asd70Cex

    ASD70CEX Ref. Description Ref. Description LVB CONNECTION KIT - CONDENSER DRYERS RX FUNCTION BUTTONS ASD70CEX USER INSTRUCTION BOOK TOP PROGRAMME BUTTONS ASD70CEX CONTROL PANEL, WHITE BOTTOM PROGRAMME BUTTONS 8X1/2 SCREW ON/OFF BUTTON ALE70CFR TOP START BUTTON ASD-ADE70C DISPLAY LENS ASD70CEX TRAY HANDLE CONTROL PANEL PCB PROGRAMME LIGHT GUIDE LX FUNCTION BUTTONS...
  • Page 71 ASD70CEX Ref. Description Ref. Description ALE70CFR OUTER DOOR, WHITE ALE70CFR MICROSWITCH DOOR CATCH FRONT AIR DUCT SENSING STRIP DOOR CATCH FRONT AIR DUCT DOOR CATCH PLATE BUSH 6X3/8 SCREW ALE70CFR MICROSWITCH LEVER PLATE ‘GDA’ THERMOSTAT MOUNTING FILTER FRONT THERMOSTAT ASD-ADE70C PLINTH 8X1/2 SCREW FRONT SEAL, DRUM ALE70CFR FRONT PANEL...
  • Page 72 ASD70CEX Ref. Description Ref. Description DRUM, ALE70CFR DRYER ALE70CFR FAN DRUM, CONDENSER DRYER BRUSH MOUNTING REAR PANEL SEAL SENSING BRUSH REAR PANEL, CONDENSER DRYER SENSING STRIP INSULATION PAD, REAR PANEL SENSING STRIP REAR PANEL+BEARING, CONDENSER DRYER DRUM SHAFT REAR BEARING SCREW REAR BEARING NOISE FILTER...
  • Page 73 ASD70CEX Ref. Description Ref. Description ALE70CFR BASE FLOAT STEM ALE70CFR WHEEL FLOAT STEM ALE70CFR MICROSWITCH ALE70CFR POMPA, PTC RING PUMP ALE70CFR FAN ALE70CFR PUMP/FLOAT COVER FAN COWL SEAL, PUMP/FLOAT COVER 7.5 UF CAPACITOR (A46CAUS) HORIZONTAL SPLASH GUARD BELT TENSION IDLER AND BRACKET VERTICAL SPLASH GUARD ALE70CFR MOTOR, TYPE 350 SEAL, PUMP/FLOAT COVER...
  • Page 74: Isl70Cex

    ISL70CEX Ref. Description Ref. Description LVB CONNECTION KIT - CONDENSER DRYERS ISL70CEX START BUTTON ISL70CEX CONTROL PANEL ISL70CEX ON-OFF BUTTON IS70VEX TIMER KNOB LIGHT GUIDE (3) ISL70CEX BUTTON LIGHT GUIDE (4) 8X1/2 SCREW CONTROL PANEL PCB (1 KNOB) WHITE TOP ISL70CEX TRAY HANDLE Service Manual Edition...
  • Page 75 ISL70CEX Ref. Description Ref. Description IS70CEX OUTER DOOR ALE70CFR MICROSWITCH DOOR CATCH FRONT AIR DUCT DOOR CATCH SENSING STRIP DOOR CATCH PLATE FRONT AIR DUCT BUSH 6X3/8 SCREW ALE70CFR MICROSWITCH LEVER PLATE FILTER ‘GDA’ THERMOSTAT MOUNTING IS70CEX PLINTH FRONT THERMOSTAT 8X1/2 SCREW FRONT SEAL, DRUM ALE70CFR FRONT PANEL...
  • Page 76 ISL70CEX Ref. Description Ref. Description DRUM, ALE70CFR DRYER ALE70CFR FAN DRUM, CONDENSER DRYER BRUSH MOUNTING REAR PANEL SEAL SENSING BRUSH REAR PANEL, CONDENSER DRYER SENSING STRIP INSULATION PAD, REAR PANEL SENSING STRIP REAR PANEL+BEARING, CONDENSER DRYER DRUM SHAFT REAR BEARING SCREW REAR BEARING NOISE FILTER...
  • Page 77 ISL70CEX Ref. Description Ref. Description ALE70CFR BASE FLOAT STEM ALE70CFR WHEEL FLOAT STEM ALE70CFR MICROSWITCH ALE70CFR POMPA, PTC RING PUMP ALE70CFR FAN ALE70CFR PUMP/FLOAT COVER FAN COWL SEAL, PUMP/FLOAT COVER 7.5 UF CAPACITOR (A46CAUS) HORIZONTAL SPLASH GUARD BELT TENSION IDLER AND BRACKET VERTICAL SPLASH GUARD ALE70CFR MOTOR, TYPE 350 SEAL, PUMP/FLOAT COVER...
  • Page 78 Indesit Company viale Aristide Merloni, 47 60044 Fabriano - Italy tel. +39 0732 66 11 - telex 560196 - fax +39 0732 66 2954 - www.indesitcompany.com Service Manual Edition Language Yate Production Dryers 2006.09.21 English...

This manual is also suitable for:

As60vexAsd70cexIsl70cex