3. COMPONENTS:

3.1 ELECTRONIC CONDENSER AND VENTED DRYERS
Conductivity sensor
1
1
NEw conductivity sensor
2
OLD conductivity sensor
filter
Traps any threads and fluff shed by the tumbled
fabrics. To be cleaned after every cycle
front fan
Draws in air from outside to cool the condenser; this
turns the steam in the condenser to water. Installed
only in the condenser model
Service Manual
Yate Production Dryers
2
Measures the moisture content of the fabrics, and
interacts with the two NTC sensors to compute the
time remaining. Readings occur every 40" approx.
Rear fan, condenser dryer
The rear fan draws in air from the room and blows it
onto the heating elements.
Rear fan, vented dryer