Display Module - Genie ZX-135/70 Service And Repair Manual

Hide thumbs Also See for ZX-135/70:
Table of Contents

Advertisement

April 2018
This table lists the various screens and menu options of the operating software. Some display menus are
for informational purpose only, while others can be used to change the machine operating parameters.
Tip-over hazard. Calibration and parameter settings must be completed by a person
trained and qualified on the repair of this machine. Failure to properly calibrate or set
parameters could cause the machine to tip over resulting in death or serious injury.
Note: The key switch must be in the off position before entering the programming mode.
Note: Use the following chart to identify the description of each LCD screen control button used in this
procedure.
Plus
Activation of the enter or previous buttons scrolls through the screens. To change parameter values or
select a setting, use the plus button (to increase or scroll forward) and the minus button (to decrease or
scroll backwards). Then press the enter button to save the new value to memory. An audible beep will
indicate a save to memory. Use the enter and previous buttons to scroll to the
button to change to
YES
Screen or Menu
Default
Operator
Part No. 1279835GT
Minus
and use the enter button to exit.
Procedure
Previous
Description
Hourmeter (on power up)
Engine speed
Fuel level (if installed)
Engine oil pressure PSI (English)
Engine oil pressure kPa (metric)
Engine temperature °F (Engiish)
Engine temperature °C (metric)
Primary boom angle to gravity
Turntable level sensor X°
direction
Turntable level sensor Y°
direction
Platform level sensor degree
Battery volts
ZX®-135/70
Service and Repair Manual

Display Module

Enter
menu. Use the plus
EXIT
Range or Selection
empty to full in 1/8th
increments
engine temp will not
display until temp is
>100°F
engine temp will not
display until temp is
>38°C
83