Outer Cover; Injector And Injector Holder - SAMES KREMLIN PPH 308 User Manual

With high voltage cable for solvent-based paints
Hide thumbs Also See for PPH 308:
Table of Contents

Advertisement

7.2.2. Outer cover

• Remove the shaping air assembly
1
Outer cover
2
O-ring
3
Shaping air shroud
• Step 2: Leave the outer cover to soak in
solvent for one hour then clean the outer
and inner surface with a cloth soaked in
solvent.
• Step 3: Clean all holes on the front of the
outer cover with a nylon brush.
• Step 4: Dry carefully with compressed air,
particularly focussing on the holes, to
ensure any paint residue is removed, then
wipe with a clean, dry cloth.
• Step 5: Check the condition of the inner
shaping air shroud and, if necessary, clean
it with a cloth soaked in solvent.

7.2.3. Injector and Injector Holder

• Remove injector
• Leave to soak for one hour in MEK solvent (methylethylketone).
• Dry carefully with compressed air.
• Reassemble in reverse order.
Index revision : C - November 2017
see § 6.6 page 34
3
2
1
Solvent
42
7030

Hide quick links:

Advertisement

Table of Contents