Colour Change And Rinsing Cycles - SAMES KREMLIN PPH 308 User Manual

With high voltage cable for solvent-based paints
Hide thumbs Also See for PPH 308:
Table of Contents

Advertisement

4.8. Colour change and rinsing cycles

Example of atomizer integration
Colour change
block
Seconds
0
Air PV - Colour
change block
Solvent PV - Colour
change block
Dump valve
PV 41
• Standard conditions: 6 bar, air, solvent and paint.
• Colour change block and rinsing block operated 1 to 1.5 metres away from atomizer.
Index revision : C - November 2017
Colours
Flow-rate adjustment restrictor (250 cc/min)
Rinsing supply circuit only
1
2
27
Flow-rate adjustment restrictor (300 cc/min)
41
PV41
PV41
11
PV11
PV11
PV32
PV32
32
PV31
PV31
31
3
4
5
6
7030