Connect The Fiber-Optic Ethernet Port; Grounding Considerations - Allen-Bradley 1783-EMS08T Installation Instructions Manual

Stratix 6000 ethernet managed switches
Table of Contents

Advertisement

ATTENTION: If the SFP module cannot be fully inserted, stop! Do not force the
module into the slot. Rotate the SFP module 180 degrees and try again.
IMPORTANT

Connect the Fiber-optic Ethernet Port

To connect the fiber-optic Ethernet port (on the SFP) in the 1783-EMS08T
switch after inserting the SFP module, follow these steps.
1. Connect the duplex LC connector end of the fiber-optic cable, in the
proper orientation, to the fiber-optic Ethernet port on the SFP module.
The SFP module is installed at the bottom of the switch. See
Optional SFP
2. Connect the other end of the cable to a device in your network or to
another switch.

Grounding Considerations

This product is intended to be mounted to a well-grounded mounting surface
such as a metal panel. The functional earth ground connection to the product is
through the specified pin on the DC connection terminals.
IMPORTANT
See publication 1770-4.1, Industrial Automation Wiring and Grounding
Guidelines, for additional information.
Rockwell Automation Publication 1783-IN004C-EN-P - April 2016
The 1783-EMS08T switch supports only 1G fiber SFP modules.
Module.
The ground connection is required at the grounding pin on the DC connection
terminals.
Stratix 6000 Ethernet Managed Switches
Install an
15