Advertisement

ArmorStratix 5700 Ethernet Managed Switches
5. Insert the ground screw into the functional ground screw opening on the front panel.
32545
6. Use a ratcheting torque screwdriver to tighten the ground screws and ring terminal lugs to the switch front panel to 0.4 N
Do not exceed the recommended torque.
7. Attach the other end of the ground wire to a grounded bare metal surface, such as a ground bus, a grounded DIN rail, or a grounded bare
rack.

Connect the Switch to a DC Power Source

You must supply a power solution for the device. Use an IP67-rated cordset or patchcord with a female-end, M12 4-pin mini-connector. Rockwell
Automation offers a Bulletin 1607 IP67-rated power supply to provide 24V DC power to the switch. Ethernet communication and control power
cables are available separately. Connect the DC power to the switch through the front panel connector.
ATTENTION: If multiple power sources are used, do not exceed the specified isolation voltage.
ATTENTION: To comply with the CE Low Voltage Directive (LVD), all power sources to this equipment must be powered from a source compliant with the
following: Safety Extra Low Voltage (SELV) or Protected Extra Low Voltage (PELV).
ATTENTION: To comply with UL restrictions, all power sources to this equipment must be powered from a source compliant with the following:
Class 2 or Limited Voltage/Current.
M12 4-pin Mini-connector
Power Connector Pinout
1
2
3
4
6
32478
DC_B+
DC_A+
DC_A-
DC_B-
Rockwell Automation Publication 1783-IN017A-EN-P - July 2017
m (3.5 lb
in).