16. Installation precautions

16-1. Indoor unit installation precautions
NOTE: The information listed below are general precautions.
Some models also include items that do not apply.
 Place where prohibited for use
• Places where there is a danger of combustible gas leakage.
• Places where sulfur gas, chlorine gas, acid, alkali, or other matter which effects equipment is
generated.
• Places where there is a lot of oil splash and steam such as kitchen or machinery room.
• Places where machinery which generates high frequencies is used.
• Ocean beaches and other areas where there is a lot of salt.
• Places where carbon fibers or any kind of powder suspended in the air.
• Inside of vehicles, ships, and other conveyances.
• Places where voltage fluctuations are large such as a factory.
 Points to remember when installing
• The product shall be installed at a place which can withstand the weight and vibration of the
indoor.
• To allow maintenance after refrigerant piping, drain piping, and electric wiring connection and
installation, provide an installation service space and an inspection port, as required.
*Installation service space is shown on
• Be careful when installing the unit at the following places.
Condition
When the
If the indoor unit is installed where the installation
ceiling is high.
height given in the installation manual is exceeded,
the temperature difference between the floor and
ceiling of the room will be large and the heating effect
will be poor.
Moreover, even if the indoor unit is installed within
the installation height, a similar phenomena will occur
when installed in a room in which the doors are
opened and closed frequently and hot air circulation
is obstructed by furniture such as desks or chairs.
When lower
When the lower level of the room is a semi-open
level directly
space such as warehouse or parking lot the surface
contacts the
temperature of the flooring will become low and the
outside air.
radiation of cold from the floor will increase.
In this case, even if the room temperature is suitable,
you may feel the foot level is cold.
When the air
When an indoor unit is installed in a position where
flow
the outlet airflow will directly contact people, a draft
distribution is
may be felt.
poor.
In addition, when there are obstructions in the path of
the intake and outlet airflow, the air distribution may
become extremely bad.
"Dimensions"
on page 33.
Contents
- 143 -
Countermeasures (Reference)
1. Switch the setting to the high
ceiling mode.
2. Install a circulator.
3. Arrange the furniture in the
room so that it does not
obstruct the hot air.
1. Adjust the louver fins or take
other measures matched to
the site.
2. Change the indoor unit outlet.