Fujitsu AUU7RLF Design & Technical Manual page 31

Air conditioner multi: 2 rooms type 3 rooms type
Hide thumbs Also See for AUU7RLF:
Table of Contents

Advertisement

 Pattern B
1. Modify the remote controller cable as follows:
• Use a tool to cut off the terminal on the end of the remote controller cable and then remove
the insulation from the cut end of the cable as shown in following figure.
• Connect the remote controller cable and connecting cable as shown in following figure.
• Be sure to insulate the connection between the cables.
2. Connect the remote controller cable.
• Connect the cable made in step 1. to the terminal (*1) of optional communication kit.
• Connect the cable from the terminal (*2) of communication kit to the indoor unit PCB.
*1:
CNC01 (for ASU7/9/12/15RLF1: UTY-XCBXZ2)
*2:
CND01 (for ASU7/9/12/15RLF1: UTY-XCBXZ2)
Connecting cable
Remote controller cable
Connecting
cable
White
Red
Remote controller cable
Terminal
(*2)
Terminal
(*1)
Communication kit
- 25 -
White
Red
Black
Insulated
connection
Black
Indoor unit PCB

Hide quick links: