Electrical Characteristics - Fujitsu AUU7RLF Design & Technical Manual

Air conditioner multi: 2 rooms type 3 rooms type
Hide thumbs Also See for AUU7RLF:
Table of Contents

Advertisement

10. Electrical characteristics

Type
Compact cassette
Slim duct
Wall mounted
Floor
Wiring spec.
(Indoor unit to outdoor unit)
MCA: Minimum Circuit Ampacity = Maximum operating current (Full load)
FLA: Full Load Ampacity
Voltage
Model name
Hz
AUU7RLF
AUU9RLF
AUU12RLF
AUU18RLF
ARU7RLF
ARU9RLF
ARU12RLF
ARU18RLF
60
208 / 230
ASU7RLF1
ASU9RLF1
ASU12RLF1
ASU15RLF1
ASU18RLF
AGU9RLF
AGU12RLF
AGU15RLF
Connection cable
Limited wiring length
- 92 -
Power supply
MCA
(V)
(A)
0.19 / 0.19
0.19 / 0.19
0.24 / 0.24
0.41 / 0.38
0.40 / 0.41
0.40 / 0.38
0.47 / 0.44
0.59 / 0.55
0.18 / 0.16
0.20 / 0.19
0.25 / 0.24
0.34 / 0.31
0.42 / 0.40
0.36 / 0.33
0.36 / 0.33
0.41 / 0.38
AWG
ft (m)
Indoor rated
Input power
FLA
(W)
(A)
17 / 18
0.15 / 0.15
17 / 18
0.15 / 0.15
22 / 23
0.19 / 0.19
38 / 39
0.32 / 0.30
47 / 33
0.32 / 0.30
47 / 49
0.32 / 0.30
56 / 58
0.37 / 0.35
71 / 73
0.47 / 0.44
15 / 15
0.14 / 0.13
17 / 17
0.16 / 0.15
22 / 22
0.20 / 0.19
28 / 28
0.27 / 0.25
40 / 41
0.34 / 0.32
35 / 32
0.29 / 0.26
35 / 32
0.29 / 0.26
40 / 36
0.33 / 0.30
14
85 (26)