Glas Craft MH II User Manual page 9

Hide thumbs Also See for MH II:
Table of Contents

Advertisement

Section 1 - Installation: Equipment Assembly
10.
Connect the whip hose assembly to the
last section of material hose.
11.
Connect jumper p/n: 22094-00 to the
plugs on material hose to complete the
circuit.
Jumper not needed with 18006-01 heated whip hose.
12.
Connect Hose Assembly and the gun as
shown. The swivel fittings on the Hose assembly
are sized differently and will attach only one way.
13.
Fluid and air connections between the sytem and
gun should now be complete and tight.
When Main Power to system console is on, the white
and black wires in the console are always live!
Disconnect or turn off Main Power source before
opening console to make any repairs or before making
any electrical repair of any type to the system.
If you do not understand the electrical hook-up
described above, consult your local GlasCraft distributor
OR a qualified electrician.
Electrical connections must be checked on a
periodic basis.
208/240 volt single phase
L1 L2 GROUND
208/240 volt three phase
L1 L2 L3 GROUND
380 volt three phase
L1 (black)
L2 (brown)
L3 (black)
L4 (blue)
GROUND (green)
transformer
14.
If more than 50 ft. of hose is used the transformer tap
setting will need to be set for proper hose length. The
COM 15V 30V
sticker on the front cover will say which tap to move
the wire to. DO NOT MOVE THE COMMON LEG!
CONNECTIONS
COM
(DO NOT
MOVE)
7
9500
D
SIZE: (ref.): 4" X 4-1/4"
H1
PRIMARY
H2
45V
60V 75V
TO HOSE
HOSE LENGTH
15V
50 FT
30V
100 FT
45V
150 FT
60V
200 FT
60V
250 FT
75V
300 FT
STE
ARIA
ARI
AR

Advertisement

Table of Contents
loading