Glas Craft MH II User Manual page 14

Hide thumbs Also See for MH II:
Table of Contents

Advertisement

Section 2 - Operation: Start-Up Instructions
2.
Remove ISO & POLY side blocks from gun.
MAKE SURE VALVES ARE OFF!
3.
Place separate clean containers under each indi-
vidual side block. Slowly open material valves
(black arrow forward) on each side block to allow
trapped air to escape the hose and material to flow
into the containers until all air is purged from the
material system.
Remember to dispense one to two gallons of material
to clear the system of grease and plasticizer that was
used during factory testing.
4.
Close the manual material valves. Material pressure
gauges should now register approximately equal
pressure.
5.
Dispose waste material properly and in accordance
with chemical suppliers instructions and local, state
and federal regulations.
Before re-assembling Side Blocks, lubrication can be
applied by dabbing a white lithium grease into holes in-
side of Gun Front Housing and wiping grease over Side-
Block Seals. Grease will purge itself when air valve is
turned on at Gun and Gun is triggered.
6.
Clean and lubricate the side blocks and seals thoroughly
and re-assemble them to the gun. Make certain that the
side block screws are tightend securely.
7.
Refer to material manufacturers operating instructions
for proper preparation of material, i.e, mixers, etc.
8.
Turn main power Switch to ON position.
9.
Turn on hose control:
a. Push in the green button.
b. Press either up or down arrow buttons on the
controller until desired temperature setting
is achieved.
12
For Programing
Use Only
Up & Down
Buttons
Green Power
On Button