Section 1 - Installation: Equipment Assembly
Optional Transfer Pump Installation
P/n: 17666-01
Optional Air Dryer Kit
P/n: 23410-00 should be installed on the ISO material
drum. Replacement cartridge pn: 23409-00.
1.
Remove large drum bunghole cover and
install material transfer pump bung adapter.
Carefully lower the transfer pump into the
drum until it touches the bottom of the drum.
Raise the pump 1/4 to 1/2 inch and tighten
bung adapter securely.
2.
Connect regulator assemblies to transfer
pumps.
3.
Connect filter assemblies to transfer pumps.
Note:
Replacement filter p/n: 17975-01. Replacement
gasket p/n: 294.
4
. Connect air lines:
1) Manifold @ unit to bottom regulator
port on ISO drum.
2) Side regulator port on ISO drum to
air port on POLY drum.
5.
Connect material hoses to material
pump inlet fittings on the unit and to
the outlet fittings at filter assemblies.