Field Service Ver. 1.0 Mar. 2006
[6]
<C>
<D>
Y104710-1
9. Move the two positioning dowels [6]
[6]
to adjust.
4583F3C522DA
• If it is deviated downward <C>, move
the positioning dowel to the left.
• If it is deviated upward <D>, move the
positioning dowel to the right.
NOTE
• Only the folding line will move.
10. Feed out the test copy and check if
there is any folding deviation.
4583F3C524DA
Service Manual
5. Mechanical adjustment
35