Swann STCL407WUK Service Information page 7

Entry level electronic condenser tumble dryers
Table of Contents

Advertisement

Indesit
Company
Auto Test Sequence
Before Starting the Auto Test, make sure the Water Container is empty, the Filter and
Condenser are Clear of fluff or lint.
Auto Test - Preparation:
If you are including the Conductivity Sensor Test when running the test procedure:
1.
Attach the magnetic end of the 270 K ohm test lead to the metal strip conductivity sensor inside
the drum.
2.
Connect the ring terminal end to an earth point on the cabinet of the machine. (The Air Duct fixing
screw is recommended).
3.
After attaching, check Earth Continuity between this ring terminal and the mains power plug Earth
pin on or the metal rear panel of the dryer, using a multimeter.
The continuity resistance reading should be 1 ohm or less.
Magnet fixed to sensing strip inside the drum
Routing of wire and resistor.
Magnet
Service Manual UK
Ring terminal end fixed under air duct screw
450 mm
7 of 34
Safe position of 270K ohm resistor
assembly with door closed
270K
2W
180 mm
Screw fixing
English

Advertisement

Table of Contents
loading

This manual is also suitable for:

8720787209Stcl408buk8721087208Stcl408wuk ... Show all