Installation - Swann STCL407WUK Service Information

Entry level electronic condenser tumble dryers
Table of Contents

Advertisement

Indesit
Company

INSTALLATION

The dryer MUST be located away from gas stoves,
hobs or heaters.
If the dryer is located under a work surface, there
10mm
must be a 10 mm gap around any top or above the
dryer and a minimum 15 mm space along each side.
This is to ensure correct air circulation.
15 mm
15 mm
CONDENSER DRYERS
Draining the dryer into an Internal Drain
If the dryer drains into an external drain, the water container will not need to be regularly emptied.
The height of the drain must be less than 1 metre from the bottom of the dryer.
Remove the existing hose from the position shown, Fig. 1. Fit a suitable length of hose (Part No.
C00279043) to the location shown in the photo (Fig. 2).
Confirm the hose is not squashed or kinked when the dryer is in its installed position.
Fig.1
Fig.3
Fig.2
Outlet Spigot
Remove this hose
New drain hose fitted
Service Manual UK
English
14 of 34

Advertisement

Table of Contents
loading

This manual is also suitable for:

8720787209Stcl408buk8721087208Stcl408wuk ... Show all

Table of Contents