FAULT FINDING
FAULT CODES
These models DO NOT display Fault Codes when the dryer develops a fault.
However an Auto Test feature is available to help diagnose faults.
Preliminary Checks:
Before performing any tests ALWAYS check that the Water Container is empty and that the Condenser
Unit and the Drum Filter are NOT blocked with fluff or lint, as this may be the cause or partial cause of
the of the fault.
2
Water container
Condenser Unit
Rear
Condenser
unit
Front
Auto Test
If a Fault is detected the dryer will not move on to the next phase of the test, but will perform the
following sequence:
>
Beep Once
>
Pause for 30 Seconds
>
Beep 3 Times
>
The End LED will display
This will Indicate the dryer has a Fault, but it will not indicate the exact cause of the problem.
Observing at which phase the auto test ends gives an indication of the type of fault and cause.
See the information on the following pages.
Service Manual UK
Tap
Catches
Handle
6 of 34
Filter
Air intake
Condenser cover
English