Siemens sitrans LR 400 Instruction Manual And Users Manual page 8

Radar level sensor
Hide thumbs Also See for sitrans LR 400:
Table of Contents

Advertisement

Solids Version
housing
connection
cover
intermediate
flange
device tag
process flange
threaded ring
Arrows required
The terminals for the power cable and the signal cable are behind the connection cover
on the left side of the housing. The signal cable must be fed in from the right through the
cable glands.
The end of the antenna must reach inside the vessel through the vessel nozzle (see
page 19).
If the device is rotated, return the orientation of the housing to its previous position with
reference to the flange, to ensure similar performance.
Page 4
SITRANS LR 400 – INSTRUCTION MANUAL
cable gland
electronics cover
display module
hand programmer
(ordered
separately)
horn antenna
7ML19985FH04