Reporting Codes

In the following
locations, 261 to 335,
other than SIA and Contact ID. For example formats like, FBI 4x2.
[INSTALLER CODE] [*] [LOCATION] [*] [SUB-LOCATION] [*] [REPORTING CODE] [*]
Location 261 to 264 Stay Zone Reporting Codes
Location Type: Extended
Each location represents a set of16 zones.
Locations to enter reporting codes if you want to report stay zones to the control room. This is for formats
other than Contact ID and SIA.
Location
261
262
Default is 00
Valid Range: 00 - FF
Location 300 Global Reporting
Location Type: Extended
Sub-Loc
Description
1
AC Fail
2
AC Restore
3
Communication Fail
4
Communication Restored
5
Phone line tamper
6
Phone line restore
7
Siren tamper
8
Siren tamper restore
Location 301 Global reporting
Location Type: Extended
Sub-Loc.
Description
1
Battery Low
2
Battery Restore
3
Auxiliary 12V Fuse failed
4
Auxiliary 12V Fuse restored
5
Installer reset required
6
Installer reset restored
7
Box tamper
the value of the reporting codes are entered for reporting formats
Profile
Zones
1
1 to 16
2
17 to 32
Explanation
Enter the code that is to be reported when the main electrical supply has
failed and the system is running on the backup battery
This reporting code is sent when the main electrical supply is restored
The X-Series can be programmed to try and communicate a number of
times via the phone line. When these attempts have been exhausted a
communication fail is sent.
When communication is restored the code is sent
If the phone line is tampered with and the line voltage goes missing an alert
is sent
When the line voltage is restored a reporting code is sent alerting the
security company
The X-Series monitors the siren and if it goes missing a signal is sent
Once the siren has been restore the security company is alerted
Explanation
After AC has failed and the system detects that the battery voltage has
reached 10.5V this code is sent to warn the company that it is about to
switch off because of the lack of power
Once charged a restore will be sent to confirm the battery is charged
If the fuse protecting the auxiliary 12V output latches off a code can be
sent to alert the security company
When the fault is corrected a restore is sent
If this option is enabled in location 211 to 218 and the alarm is tripped in
the partition that it is enabled in, the alarm cannot be armed until the
installer code is entered.
Once the installer code has been entered after an alarm has tripped a
restoral will be sent
On the alarm panel is a connector that a switch can be connected to
Location
Profile
263
3
33 to 48
264
4
49 to 64