Adjustment
Forward and back adjustment of needle and presser.
1. Turn the pulley by hand, and insert the tip of the needle into the needle hole.
2. Loosen the locknut.
3. Adjust the needle tip to the front/back center position of the needle hole using the set screw (socket (CP) M4X12).
4. Tighten the lock nut.
Socket set screw (CP, M4x12)
Lock nut
Needle hole
Needle tip
4 - 18