Siemens SCALANCE X-200 Operating Instructions Manual page 72

Simatic net, industrial ethernet switches
Hide thumbs Also See for SCALANCE X-200:
Table of Contents

Advertisement

Technical specifications
For X208PRO (degree of protection IP65/67)
With the X208PRO, splitting of the cables (as above) is not permitted either. The following
cables are permitted in the specified lengths:
● 0 to 55 m:
IE TP torsion cable with IE FC M12 Plug PRO
● 0 to 85 m:
IE FC TP marine / trailing / flexible / FRNC / festoon / food cable with IE FC M12 Plug
PRO
● 0 to 100 m:
IE FC TP standard cable with IE FC M12 plug PRO
Permitted cable lengths - fiber-optic
Type
1 - 50 m
980/1000 plastic optical
fiber (POF)
X204-2
X204-2TS
X204-2FM
X204-2LD
X204-2LD TS
X206-1
X206-1LD
X212-2
X212-2LD
XF204-2
XF206-1
X200-4P IRT
X201-3P IRT
X201-3P IRT PRO
X202-2IRT
X202-2P IRT
X202-2P IRT PRO
72
1 - 100 m
200/230 polymer cladded
fiber (PCF)
6 dB max. permitted cable
attenuation with 3 dB link
power margin
-
-
-
-
-
-
-
-
-
-
-
+
+
+
+
+
+
-
+
+
+
+
0 - 4000
Glass FO cable
62.5/125 µm glass fibers
0 - 5000
Glass FO cable
50/125 µm glass fibers
≤ 1 dB/km at 1300 nm;
600 MHz x km;
6 dB max. permitted cable
attenuation with 3 dB link
power margin
-
+
-
+
-
+
-
-
-
-
-
+
-
-
-
+
-
-
-
+
-
+
-
-
-
-
+
-
-
Operating Instructions, 03/2015, C79000-G8976-C284-06
0 - 26000 m
glass FO cable
9/125 µm single mode
fiber;
0.5 dB/km at 1300 nm;
13 dB max. permitted
cable attenuation with 2
dB link power margin
-
-
-
+
+
-
+
-
+
-
-
-
-
-
-
-
-
SCALANCE X-200

Hide quick links:

Advertisement

Table of Contents
loading