Connecting accessories Dimensions and setting-out coordinates 6 Commissioning and adjusting Sound pressure levels Technical specifications Preparations Filling and venting the heating medium sys- Energy labelling Electrical circuit diagram Balance temperature Index Stop temperature Soft-starter NIBE™ F2300 Table of Contents |...
1 Important information Marking Safety information The CE marking means that NIBE ensures that the This manual describes installation and service proced- product meets all regulations that are placed on it ures for implementation by specialists. based on relevant EU directives. The CE mark is obligat-...
Do not install the outdoor unit in a location where insects Use main switch with sufficient breaking capacity. and small animals can inhabit. NIBE™ F2300 Chapter 1 | Important information...
Country specific information - When filling refrigerant, the refrigerant must always leave the bottle in liquid form. Installer manual This installer manual must be left with the customer. Chapter 1 | Important information NIBE™ F2300...
Page 7
Electricity (page 17) Fuses property Safety breaker Earth circuit-breaker Heating cable type/effect Fuse size, heating cable (F3) Communication cable connected Miscellaneous Condensation water pipe Insulation condensation water pipe, thickness (if KVR 10 is not used) NIBE™ F2300 Chapter 1 | Important information...
NIBE Energy Systems France Sarl, Zone industrielle RD 28, Rue du Pou du Ciel, 01600 Reyrieux Tel : 04 74 00 92 92 Fax : 04 74 00 42 00 E-mail: info@nibe.fr www.nibe.fr NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG Tel: 0845 095 1200 Fax: 0845 095 1201 E-mail: info@nibe.co.uk www.nibe.co.uk...
8). Care must be exercised so that the heat pump is not ■ scratched during installation. min 300 mm Do not place F2300 directly on the lawn or other non solid surface. NIBE™ F2300 Chapter 2 | Delivery and handling...
Page 10
Caution example a lawn, we recommend that a crane that can lift it to the set up location is used. When the F2300 is If none of the recommended alternatives is lifted by crane the packaging must be untouched and...
Page 11
The outlet of the condensation water pipe must be at frost free depth. If the house has a cellar the stone caisson must be po- Route the pipe downward from F2300. sitioned so that condensation water does not affect The condensation water pipe must have a water seal the house.
Ø 1455 Installation area The distance between F2300 and the house wall must be at least 400 mm. Clearance above the F2300 should be at least one metre. Fritt utrymme bakom Free space behind 600 mm Minimum free space Minimum free space Minimum distance during use Min.
Page 15
Pipe connections Connection, heating medium out of F2300 Connection, heating medium in to F2300, XL20 Service connection, high pressure XL21 Service connection, low pressure XL40 Connection, drain condensation water trough Sensors etc. High pressure pressostat Low pressure pressostat BP10 High pressure pressostat...
Pipe installation must be carried out in accordance with current norms and directives. F2300 can only operate up to a return temperature of F2300 -14, 20 FIGHTER 2300-14, 20 about 55 °C and an outgoing temperature of about 65 °C from the heat pump.
Docking alternatives F2300 can be installed in several different ways, for example with integrated or external control. The safety equipment must be installed in accordance with current regulations for all docking options. See www.nibe.eu for more docking options. When docking with F2300 a minimum available system volume of at least 20 litres per kW output on the heat pump is recommended.
Charge pump for F2300 can be connected to separ- ■ ate supply or to terminal block (X3). NOTE! If F2300 is not powered and the charge pump is connected to the terminal block (X3) there is a risk of freezing A common alarm can be connected to terminal (X4).
Incoming supply cable is supplied and factory connec- ted to the terminal block -X1. Approx. 1.8 m cable is accessible outside the heat pump. On installation the unions must be mounted on the rear of the heat pump. Chapter 5 | Electrical connections NIBE™ F2300...
Page 21
Connecting external control voltage Charge pump To let F2300 control the charge pump (GP12), connect NOTE it to the terminal block X3:1(PE), 3(L) and 4(N). Pump Mark up any junction boxes with warnings for activity is dependent on the status of F2300, heat- external voltage.
Page 22
External heating cable (KVR 10) Cable routing The following image displays the recommended cable F2300 is equipped with a plinth for external heating routing from the junction box to the condensation cable EB14, not supplied). The connection is fused with water trough on the outside of F2300.
Downtime AA21-J6 Stillestånd do not apply when F2300 is controlled by a NIBE indoor module. Max load across the relay contactors is 250V 2A. Thermostat control During operations without the need of the additional...
For connection of indoor module, see relevant manual on www.nibe.eu. External indication of main alarm F2300 is equipped with a contact for external indication of common alarms. The function becomes active with all types of existing alarms. Max load on the relay con- tact is250V 2A.
1. The heating medium system is filled with water to the required pressure. F2300 is equipped with a collar heater that can heat 2. Vent the system using the venting nipple on the the fan collar if necessary (not activated upon delivery).
AA21:J2) or thermostat, terminal block (X5) must not be connected. 2. Turn the isolator switch on. 3. Ensure that the F2300 is connected to the power source. 4. Check that the motor circuit-breaker (FC2) is on. 5. Check that the LED on phase sequence sensor (BA1) lights red.
For the heat pump to function correctly all year, the Adjustment of charge flow charge flow must be adjusted using the NIBE indoor F2300-20 kW Delta T between water supplying and return EN255 dT (K) dT (K) module or according to the procedure below, with other controls.
The indoor module communicates with F2300 which Minus button means that settings and measurement values from F2300 can be adjusted and read off in the indoor The minus button (S2) is used to browse module. through the channel system (backwards) or lower the value of the selected parameter.
Shows the current channel. Change channels using the Plus button or the Minus button. Fan on, low speed Value: 01 Fan on, high speed Shows the current value. Increase/decrease value using the plus button respective minus button. NIBE™ F2300 Chapter 7 | Control - Introduction...
B = Set temperature for cold outdoor air (channel A7). A = Set temperature for cold outdoor air + 2.1 °C. Outdoor temperature Utelufttemperatur utelufttemp. Chapter 7 | Control - Introduction NIBE™ F2300...
Page 31
(if the pressure has fallen), not correct and therefore displays too low temper- otherwise there is a constant high pressure alarm ature (at cold outdoor air). (alarm 06). NIBE™ F2300 Chapter 7 | Control - Introduction...
Page 32
5. The temperature on the flow temperature sensor falls below 4 °C. Chapter 7 | Control - Introduction NIBE™ F2300...
Shows the compressor's operating time in hours, with the indoor module. accumulatively. For example 3 x F2300 in the same system are alloc- Shows the operating hours for connected additional ated the addresses 1, 2 and 3. The F2300 that pro- heat, accumulatively.
Page 34
1 and 120 minutes. Factory setting 120 minutes. Stop temperature, the set outdoor air temperature value when the downtime relay is activated, F2300 stops. When the stop temperature is set between 0 °C and -25 °C the supply temperature is limited linearly from -10 °C / 65 °C to -25 °C / 63 °C (see...
■ NOTE Fuses have tripped. ■ As F2300 can be connected to a large number Replace the fuse or reset the MCB. ■ of external units, these should also be checked. Cold outdoor air. Indicated as 03 in channel S1.
Page 36
Temperature sensor, heating medium return line BT12 Temperature sensor, condenser supply line BT14 Temperature sensor, hot gas BT15 Temperature sensor, fluid pipe BT16 Temperature sensor, evaporator BT17 Temperature sensor, suction gas BT28 Ambient temperature sensor Chapter 9 | Disturbances in comfort NIBE™ F2300...
Heating thermostat VT 10 Heating thermostat Part no. 418 801 Indoor module VVM 500 Part no. 069 400 SMO 20 Control module Part no. 067 224 SMO 40 Control module Part no. 067 225 NIBE™ F2300 Chapter 10 | Accessories...
600 mm Minimum free space Minimum free space 600 mm Minimum distance during use Min. avstånd vid användning of several F2300 av flera F2300 Min. avstånd vid användning av flera F2300 Fritt utrymme framför Free space in front Min. avstånd vid användning...
F2300 is usually placed next to a house wall, which gives a directed sound distribution that should be F2300 works with low fan speed or high fan speed considered.
°C -25/40 Defrosting system Reversing Heating medium Min/Max system pressure heating medium 0.05/0.3 (0.5/3 bar) Nominal flow (Min flow during defrosting) 0.33 0.47 Min/Max flow 0.33/0.67 0.47/0.94 Internal pressure drop at nominal flow Chapter 11 | Technical data NIBE™ F2300...
Page 43
Miscellaneous Enclosure class IP 24 Colour Dark gray Part No. 067 063 067 064 SCOP & Pdesign F2300 according to EN 14825 14 kW 20 kW Pdesign SCOP Pdesign SCOP SCOP 35 Average climate (Europe) SCOP 55 Average climate (Europe) 13.5...
Page 44
Working area Water temperature °C Supply temperature Return temp Outdoor air temperature °C During shorter time it is allowed to have lower working temperatures on the water side, e.g. during start up. Chapter 11 | Technical data NIBE™ F2300...
The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added to the package, the overall efficiency of the package should be recalculated. NIBE™ F2300 Chapter 11 | Technical data...
Page 46
For heat pump combination heater Declared load profile for water heating Water heating energy efficiency ƞ Daily energy consumption 10.03 Daily fuel consumption elec fuel Annual energy consumption 2,203 Annual fuel consumption Chapter 11 | Technical data NIBE™ F2300...
Page 47
For heat pump combination heater Declared load profile for water heating Water heating energy efficiency ƞ Daily energy consumption 10.32 Daily fuel consumption elec fuel Annual energy consumption 2,266 Annual fuel consumption NIBE™ F2300 Chapter 11 | Technical data...
Page 53
The heat pump design, 12 Component list electrical cabinet, 14 Component location electrical cabinet, 14 Component locations, 12 List of components, 12–13 Thermostat control, 21 Transport and storage, 7 Troubleshooting, 33 Sensor placement, 34 NIBE™ F2300 Chapter 12 | Item register...
Page 55
Återvinning Lämna avfallshanteringen av emballaget till den installatör som installerade produkten eller till särskilda avfallsstationer. När produkten är uttjänt får den inte slängas bland vanligt hushållsavfall. Den ska lämnas in till särskilda avfallsstationer eller till återförsäljare som tillhandahåller denna typ av service. Felaktig avfallshantering av produkten från användarens sida gör att administrativa påföljder tillämpas i enlighet med gällande lagstiftning.