ORing warrants that all ORing products are free from defects in material and workmanship for a specified warranty period from the invoice date (5 years for most products). ORing will repair or replace products found by ORing to be defective within this warranty period, with shipment expenses apportioned by ORing and the distributor.
M12 connector to ensure tight and robust connections, the device guarantees reliable operation against environmental disturbances, such as vibration and shock, and are ideal for rolling stock applications. The router comes with an IP-67 waterproof housing to protect it ORing Industrial Networking Corp...
2. LED for PWR1 status 7. LED for LAN connection 3. LED for PW2 status 8. Reset button 4. LED for PoE status 9. LAN port 5. LED for WAN connection 10. Connector for WiFi antenna 11. SIM card slot ORing Industrial Networking Corp...
PWR2 DC power 2 activated Green Power supplied over Ethernet cable Port is linked Green Blinking Transmitting data WLAN activated WLAN Green Blinking Transmitting data via WLAN Green WAN activated 2.2 Top Panel 1. Antenna connectors ORing Industrial Networking Corp...
The device can be fixed to a pole or the wall using the supplied mounting plate. Make sure the connectors on the bottom panel are facing down when installing to prevent water intrusion. Mounting plate ORing Industrial Networking Corp...
Follow the steps below to install the device to the wall. Step 1: Attach the mounting plate to the back of the device using four screws. The plate can be attached vertically or horizontally to the device based on the space available. ORing Industrial Networking Corp...
When installing the device to a pole: Step 1: Attach the mounting plate to the back of the device using four screws. The plate can be attached vertically or horizontally to the device based on the space available. ORing Industrial Networking Corp...
Page 11
TGAR-W1601+ Series User Manual Step 2: Thread the two supplied metal mounting straps through the large slots on the mounting plate and then put the straps around the pole. ORing Industrial Networking Corp...
Step 1: insert the negative/positive wires into the V-/V+ terminals, respectively. Step 2: to keep the DC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector. ORing Industrial Networking Corp...
UTP 100 m (328ft) Definition BI_DC+ BI_DD+ BI_DD- BI_DA- BI_DB+ BI_DA+ BI_DC- BI_DB- 4.2 Wireless Antenna The device comes with two WiFi antennas with N-type female connectors. You can also use external RF cables and antennas with the connectors. ORing Industrial Networking Corp...
4.3 Cellular Antenna The device is packed with one or one 3G or 4G antenna. External RF cables and antennas can also be used with the connector. ORing Industrial Networking Corp...
A login window will pop up where you can enter the default login name admin and password admin. For security reasons, we strongly recommend you to change the password. Click on System Tools > Login Setting after logging in to change the password. ORing Industrial Networking Corp...
On top of the Home screen shows information about the firmware version, uptime, and WAN IP address. Label Description Firmware Shows the current firmware version Uptime Shows the elapsed time since the AP router is started Wan IP Shows WAN IP address ORing Industrial Networking Corp...
Check to allow for reconnection when links fail UIM Status Shows the status of SIM card Operations Click Connect to start modem/3G connections or Disconnect to shut down connections Link Status Shows the status of connections Modem Status Shows information about the modem ORing Industrial Networking Corp...
Page 18
IP address automatically, this option will be automatically selected accordingly. Use the following Specifies a DNS server address manually. You can enter two DNS server addresses as the primary and secondary options. addresses ORing Industrial Networking Corp...
IP address from a DHCP server. The router comes with a built-in DHCP (Dynamic Host Control Protocol) server which assigns an IP address to a computer (DHCP client) on the LAN automatically. The router can also serve ORing Industrial Networking Corp...
Page 20
DHCP Forwarder will forward DHCP messages to a server on the Internet to handle DHCP requests. If you choose DHCP Forwarder, enter a DHCP server IP address. DHCP Server Enables or disables the DHCP server function. The default ORing Industrial Networking Corp...
You can set the device to work in AP mode. This is the most common mode for all wireless APs. In this mode, the AP will act as a central connection point which other wireless clients can connect to. ORing Industrial Networking Corp...
Page 22
WEP: WEP (Wired Equivalent Privacy) is a wireless security protocol for WLAN. WEP will encrypt data transmitted on the WLAN. WPA/WPA2 Personal: uses a pre-shared key for authentication. This pre-shared key is then dynamically sent between the AP and clients. ORing Industrial Networking Corp...
Page 23
Select one of the keys to be the active key Key 1 to 4 You can input up to four encryption keys. When you set security type as WPA/WPA2-Personal, the following fields will appear to allow you to configure individual settings. ORing Industrial Networking Corp...
Page 24
WPA RADIUS Server. You need a RADIUS or other authentication server on the network. Available values include TKIP, AES, and TKIP/AES mix. WPA-PSK Encryption Type uses TKIP encryption, WPA2-PSK uses encryption. TKIP/AES provides the most reliable security, and is ORing Industrial Networking Corp...
Page 25
When you configure the remote access server for RADIUS authentication, the credentials of the connection request are passed to the RADIUS server for authentication and authorization. If the request is both authenticated and authorized, the RADIUS server sends an accept ORing Industrial Networking Corp...
Choose a DDNS service provider from the list User Name Enter the user name of your DDNS account Password Enter the password of your DDNS account Domain Enter the domain name provided by your dynamic DNS service provider ORing Industrial Networking Corp...
Time from Browser 5.2.2 Networking Setting This section will guide you through various networking settings, including wireless, NAT, firewall, VPN, VRRP, and routing protocol. Wireless Setting – Advanced Setting This page allows you to set up wireless configuration. ORing Industrial Networking Corp...
Page 28
The value should remain at the default 2346 (the range is 256 - 2346 bytes). If you experience a high packet error rate, you may slightly increase the value. Setting the value too low may result in poor network performance. Only ORing Industrial Networking Corp...
Assign the value roaming channels Sensitivity Configures signal sensitivity Scan Interval Configures scan interval Wireless Setting – MAC Filter This page allows you to set up MAC filters to allow or deny wireless clients to connect to the ORing Industrial Networking Corp...
FTP, Web or game servers. A public port must be defined for the virtual server on your router in order to redirect traffic to an internal LAN IP address and LAN port. Any PC used as a virtual server must have a static or reserved IP address. ORing Industrial Networking Corp...
To use this function, you need to set an internal computer as the DMZ host by entering its IP address. Adding a client to the DMZ may expose your local network to a variety of security risks, so use this function carefully. ORing Industrial Networking Corp...
Application: The application that generates this port forwarding. Ext Port: The port opened on WAN Protocol: The protocol type Int Port: The port redirected to the local computer IP Address: The IP address of local computer to be redirected to ORing Industrial Networking Corp...
Shows the information of all IP filters. Click Edit to edit the entry or Del to delete the entry. Firewall Setting – MAC Filter This page enables you to deny or allow LAN computers to access the Internet based on their MAC addresses. ORing Industrial Networking Corp...
To set up your router as an Open VPN server, you need to install openvpn client software for your Windows-based PC. You can download it from http://openvpn.net/download.html#stablel. ORing Industrial Networking Corp...
Page 35
Connection to Open VPN Server When you enable Open VPN Client, you need two routers to create site-to-site VPN connections. The server IP and client IP address should be within the same network domain. Open VPN Server and Client Connection ORing Industrial Networking Corp...
Page 36
Select UDP or TCP protocol depending on your needs. TCP is more reliable than UDP, but UDP performs better than TCP. It is recommended to use UDP if the distance between VPN server and client is short; otherwise, use TCP. ORing Industrial Networking Corp...
Connect to my work space (VPN) > Use VPN to Internet, and then enter the user name and password set in the page. After setting up a new connection, you can make configurations in the following page. ORing Industrial Networking Corp...
Enter the username and password pairs in the form of user * pass *. Multiple username and password pairs are allowed. Vpn Setting – PPTP Client If a router wants to link to the routers in different networks, you should enable PPTP client in the following page. ORing Industrial Networking Corp...
Page 39
TGAR-W1601+ Series User Manual ORing Industrial Networking Corp...
All routers in the virtual router group share the same VRID and VRIP. The master router provides primary routing and the backup routers monitor the status of the master router and become active if the master router fails. ORing Industrial Networking Corp...
Page 41
VRID on the router that owns the default gateway interface. The other router in the VRID does not own the IP address associated with VRID but provides the backup path if the Master router becomes unavailable. ORing Industrial Networking Corp...
When RIPv1 & v2 is Disabled, the router will operate in static routing mode, which means routers forward packets using either route information from route table entries that you manually configure or the route information that is calculated using dynamic routing algorithms. ORing Industrial Networking Corp...
Page 43
BGP; however, the device only supports RIP (Routing Information Protocol). Do not choose Disable in the RIPv1 & v2 list if you want to enable Dynamic Routing. After clicking Apply, more information will be displayed in Current Routing Table. ORing Industrial Networking Corp...
Page 44
Choose Disable to disable dynamic routing or other options to configure the interfaces for dynamic routing Telnet Setting This option is only available when dynamic routing is enabled. It allows you to make detailed configurations via simple comments. Routing Topography ORing Industrial Networking Corp...
Choose HTTPS if you want a secure connection. Port Choose a web management page port number. For HTTP, default port is 80. For HTTPS, default port is 443. Router Restart This page allows you to configure restart settings for the router. ORing Industrial Networking Corp...
ORing launches new firmware constantly to enhance router performance and functions. To upgrade firmware, download new firmware from ORing’s website to your PC and install it via Web upgrade. Make sure the firmware file matches the model of your router. It will take several minutes to upload and update the firmware.
Internet or if the WAN connection is OK. Enter a domain name or IP address in the destination box and click Ping to test. Event Warning When an error occurs, the router will notify you through system log, e-mail, SNMP, and ORing Industrial Networking Corp...
Page 48
Enter the IP address of a remote server if you want the logs to be stored remotely. Leave it blank will disable remote syslog. Syslog Server Port Specifies the port to be logged remotely. Default port is 514. ORing Industrial Networking Corp...
Enter a backup host to be used when the primary host is unavailable. Server Port Specifies the port where MTA can be contacted via SMTP server E-mail Address 1-4 Enter the mail address that will receive notifications ORing Industrial Networking Corp...
Page 50
NMS by keeping track of various operational aspects of the AP system. You can enable or disable the function. SNMP Trap Enter the IP address of the SNMP server which will send out traps Server 1-4 generated by the AP. ORing Industrial Networking Corp...
System Log The router will constantly log events and activities and provide the files for you to review. You can click Refresh to renew the page or Clear Logs to clear all or certain log entries. ORing Industrial Networking Corp...
TGAP-W1601+ Series User Manual Traffic Statistics This page displays network traffic statistics for packets both received and transmitted through Ethernet ports and wireless connections. Wireless Link List This page displays the Mac address of all wireless clients connected. ORing Industrial Networking Corp...
TGAR-W1601+ Series User Manual echnical pecifications ORing WLAN Access Point TGAR-W1061+-3G-M12 TGAR-W1061+-4G-M12 Model Physical Ports 10/100/1000Base-T(X) Ports in M12 Auto MDI/MDIX (8-pin A-coding) Fully compliant with IEEE 802.3af Power Device specification Over load & short circuit protection PoE P.D. port Isolation Voltage: 1000 VDC min.
Page 54
FCC Part 15, CISPR (EN55022) class A, EN50155 (EN50121-3-2) EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 Shock IEC60068-2-27, EN61373 Free Fall IEC60068-2-32 Vibration IEC60068-2-6, EN61373 Rail Traffic EN50155 Cooling EN60068-2-1 Dry Heat En60068-2-2 Safety EN60950-1 Warranty 5 years ORing Industrial Networking Corp...
“Digital Apparatus,” ICES-003 of Industry Canada. Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe B prescrites dans la norme sur le matérial brouilleur: “Appareils Numériques,” NMB-003 édictée par l’Industrie. ORing Industrial Networking Corp...
Page 56
Avertissement d'exposition RF: L'équipement est conforme aux limites d'exposition aux RF établies pour un incontrôlés environnement. L'antenne (s) utilisée pour ce transmetteur ne doit pas être co-localisés ou fonctionner en conjonction avec toute autre antenne ou transmetteur. ORing Industrial Networking Corp...
Need help?
Do you have a question about the TGAR-W1061 Plus-3G-M12 and is the answer not in the manual?
Questions and answers