Summary of Contents for US Water Systems Oxi-Gen 150-MO-1
Page 1
Installation, Operation and Maintenance Manual US Water Matrixx Oxi-Gen Iron, Sulfur and Manganese Eradication System Oxi-Gen 150-MO-1 Oxi-Gen 150-MO-2 Oxi-Gen 150-MO-3 Oxi-Gen 150-MO-4 US Water Systems, Inc. 1209 Country Club Road Indianapolis, IN 46234 1-800-608-8792 info@uswatersystems.com www.uswatersystems.com ...
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System Table of Contents System Overview and Specifications ..................3 How Your Oxi-Gen System Works/Backwash Frequency Table ........... 4 Stenner Injection System Specifications ................5 Injection System Installation Instructions ................6 Carbon Filter Media and Valve Installation ................
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System System Overview and Specifications US Water has pioneered the use of hydrogen peroxide in water treatment for the eradication of iron (rust), sulfur (hydrogen sulfide odor) and manganese for nearly 20 years. It can truly be called an "Eradication System"...
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System How Your Oxi-Gen Water Treatment System Works The Oxi-Gen iron, sulfur and manganese eradication system uses Hydrogen Peroxide (H2O2) to oxidize contaminants in your water source. The chemical name for hydrogen peroxide is H2O2.
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System System Components Stenner Proportional Injection System Specifications Stenner Econ FP Multiple Function A ll-in-One Pump The Econ FP is compact, easy to program and can respond to flow input from a variety of water conditioning equipment Water Meter The pump will accept a pulse input from a dry contact water meter and has adjustable ...
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System System Components Stenner Econ FP Injection System Installation Instructions Note: If there is sediment in the water, it should be removed prior to the injection system using a pleated filter and or multi-media filter.
Page 7
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System System Components CONTROL PANEL GUIDE –BUTTONS The control panel has a backlit LCD display;; when operating it will display the operating modes and the % setting. Following are the six buttons for programming the modes of operation. Scrolls through the available modes of operation: 1 SECOND, 5 SECONDS, 10 SECONDS, 20 ...
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System System Components Media Installation Assembly Instructions 1. Remove the tanks from carton. 2. Verify the riser is centered in the tanks. There is an indentation in the bottom of the tanks that will center the riser.
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System Hydrogen Peroxide Injection System Assembly & Installation Instructions 1. Remove the Stenner Econ FP pump and solution tank from the box. 2. Mount the pump mounting bracket to the tank using customer supplied screws. Be sure the bracket is in- stalled so the control panel is facing up.
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System Carbon Filter Installation Instructions WATER PRESSURE: A minimum of 20 pounds of water pressure is required for regeneration valve to operate effectively. ELECTRICAL FACILITIES: An uninterrupted alternating current (A/C) supply is required. Note: Other voltages are avail- able.
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System Valve Programming 1. If the valve is locked press the menu button for 3 seconds to unlock the valve. Chart on Page 17. 1. No push the up and down arrows simultaneously for 3-5 seconds to enter the master programming mode. 2.
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System Start Up Some of these steps have been covered. However, this will help ensure the system is started properly. 1. Plug the injection pump into a 110v outlet. 2.
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System What To Expect and Routine Maintenance Now that the Matrixx Oxi-Gen system has been installed here are a few things to expect;; 1. The Matrixx Oxi-Gen system will produce iron, sulfur and manganese free water immediate- ly after installation.
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System Maintenance Schedule Component Action Frequency Replacement Part # Existing Well Pressure Drain tank until the water runs 1-6 Months Tank clear. Injection Pump Tube Inspect pump tube and replace 1-5 Years 411-EC30G-2 as needed.
Page 15
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System Flow Schematic Single Tank System...
Page 16
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System Flow Schematic Dual Tank System...
Installation, Operation and Maintenance Manual Matrixx Oxi-Gen MO-1, MO-2, MO-3, MO-4, System Warranty Matrixx Oxi-Gen Limited Lifetime Warranty For the lifetime of the original purchaser, at the original residential These warranties are in lieu of all other warranties expressed ...