Unit Location; Unit Limitations; Component Location - York LATITUDE JP024-060 Installation Manual

R-22, 13 seer
Table of Contents

Advertisement

If components are to be added to a unit to meet local codes,
they are to be installed at the dealer's and/or the customer's
expense.
High Efficiency Enhanced
Copper Tube/Aluminum Fin
Outdoor Coil
Compressor Rigidly
Figure 1: Component Location
Table 1: Unit Limitations
Size
(Tons)
024
(2.0)
030
(2.5)
036
(3.0)
042
(3.5)
048
(4.0)
060
(5.0)

Unit Location

Several important factors must be considered before selecting
the site for this unit:
1.
Site – Select a solid level position, preferably on a concrete
slab, slightly above grade level and parallel to the home.
Johnson Controls Unitary Products
Direct Drive
Condenser Fan Motor
High Efficiency
Mounted
Decorative Protective
Coil Guard
Unit Voltage
208/230-1-60
208/230-1-60
208/230-1-60
208/230-3-60
208/230-1-60
208/230-1-60
208/230-3-60
208/230-1-60
208/230-3-60
460-3-60
Size of unit for proposed installation should be based on heat
loss/heat gain calculations made in accordance with industry
recognized procedures identified by the Air Conditioning
Contractors of America.

Unit Limitations

Applied Voltage
Min
Max
187
252
187
252
187
252
187
252
187
252
187
252
187
252
187
252
187
252
432
504
2.
Proximity to home or building – The length of the supply
and return ducts should be kept to a minimum with no
sharp bends. Consideration should be given to the
distance and routing of electrical service to connect the
unit. Try to select a site for the unit that it is as close as
possible to the proposed return grille location. Unit may be
positioned to draw air from underneath structure.
High Efficiency Enhanced
Copper Tube/Aluminum Fin
door Coil
Blower Service
Access Panel
X13 Direct Drive
Blower Motor
Refrigerant
Connections
Control Box Service
Access Panel
Heavy Gauge
Base Rails
Outdoor DB Temp
Max (°F)
125
125
125
125
125
125
125
125
125
125