Advanced Settings - Mantracourt T24-ANTA User Manual

T24 series wireless telemetry
Table of Contents

Advertisement

Advanced Settings

You should not normally need to change these settings.
Items you can change:
Sleep Delay
Data Tag
Transmit power
Mantracourt Electronics Limited
Here you can enter a delay in seconds after which the transmitter module will
return to deep sleep if no Keep Awake message is heard from software,
handheld or other receiving modules. The default is 60 seconds.
The data transmitted by the transmitter module is marked with a Data Tag
which is a 2 byte hexadecimal code. By default this is set to the last 2 bytes of
the module ID (or to put it another way, the last 4 characters of the module ID).
If by some chance you had two transmitter module modules that would be
working on the same channel and had the same last 4 characters in their ID (1 in
65,535 chances) you may want to change the data Tag of one of the modules
and perform pairing again with the T24-HS handheld.
Set the transmit power level from 0 – 100%.
Default is 100%
148
T24 Telemetry User Manual

Advertisement

Table of Contents
loading

Table of Contents