6. remove the backplate from the mixer by
loosening the grubscrew with a 2.5 mm
hexagonal key.
7. Secure the backplate to the wall using the
screws.
8. For Rear Entry Supplies Only:
a)
Fit the concealing plates over the inlet
pipes.
Note! apply silicone sealant to the back
face of the flange.
apply Silicone Sealant
9. Caution! It is essential at this point
that the supply pipework is thoroughly
flushed through before connection to the
mixer. Failure to do so may result in product
malfunction and will not be covered under the
guarantee.
10. Fit the compression nuts and olives onto the
pipework.
11. align the mixer with the pipework and fit
onto the backplate. Minor misalignment of
the pipework can be accommodated by the
inlets, which are adjustable between 139 and
153 mm centres.
Important! Make sure that the hot and cold
inlets on the mixer correspond with the hot and
cold inlet supplies.
Backplate
Screw
concealing Plate
12. Using a suitable tool, tighten the waterway
securing ring until it abuts the adjustable inlet
preventing outward movement.
Waterway
Securing ring
concealing cap
(assembled)
13. assemble the concealing caps and securing
clips and push into the elbow.
14. tighten the compression nuts onto the mixer
with a suitable spanner.
Caution! take care not to damage the chrome
surfaces.
15. tighten the grubscrew to secure the mixer to
the backplate.