Solid Wall or Stud Partition Fixing
using Securing Brackets
1. refer to section: 'Rear Fixing into Solid Walls
or Stud Partitions' and follow instructions
1 to 4.
2. remove the plasterboard and/or brick work to
a minimum depth of 62 mm.
62 mm Min
3. Fit the securing brackets to the mixer with the
bracket securing screws.
Important! Make sure that the correct holes
are used, otherwise the backplate cannot be
fitted.
Backplate
Securing holes
4. Make sure that the mixer is level and mark the
positions for the countersunk fixing holes on
the wall.
5. For solid walls drill two 6 mm holes for the wall
plugs.
4 mm Min
Finished Wall
Finished Wall
Surface
Securing
Bracket
24 mm Max
Finished Wall
countersunk
Fixing hole
14
6. Fit the hot and cold supply pipework (Hot -
Left, Cold - Right).
7. Caution! It is essential at this point
that the supply pipework is thoroughly
flushed through before connection to the
mixer. Failure to do so may result in product
malfunction and will not be covered under the
guarantee.
8. remove the wall brackets from the mixer.
9. Make sure that the olives are fitted, connect
the hot and cold supply pipes and tighten the
compression nuts.
10. Refit the wall brackets to the mixer, fit the wall
plugs and fix the mixer to the wall with the
screws provided.
Note! For stud partition installations alternative
fixings may be required (not supplied).
14. connect the outlet pipework and install the
rac assembly or Bir assembly, before
continuing with the installation of the mixing
valve.
RAC assembly, go to section: 'installation,
RAC Assembly'.
BIR assembly, refer to your shower fittings
installation and user guide then continue with
instruction 12.
outlet Pipe
to Fittings
hot Supply
12. turn on the water supplies and check for
leaks
cold Supply
Screws