Alarm ID
Name
202
Invert
Module
Fault
Issue 10 (2017-07-30)
Severity
Causes
Major
Abnormal external conditions
have triggered converter
circuit protection inside the
SUN2000. The possible causes
are as follows:
Reason ID = 4
A sharp drop in grid
voltage or a short-circuit
has occurred, resulting in
high output current from
the SUN2000.
Reason ID = 13
A sharp drop in grid
voltage or a short-circuit
has occurred, resulting in a
fault in the voltage check
circuit of the SUN2000.
Reason ID = 14
A sharp drop in grid
voltage or a short-circuit
has occurred, resulting in
instantaneous high output
current from the SUN2000.
Reason ID = 16
The grid DC current
exceeds the allowed range.
Reason ID = 17
The grid voltage or
frequency is abnormal.
Reason ID = 20
The SUN2000 output
short-circuits, leading to a
sharp increase in output
current.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8 Maintenance
Measures
Reason ID = 4, 13, 14, 16, or 17
a. The SUN2000 monitors its
external working conditions in
real time and automatically
reverts to normal operating status
after the fault is rectified.
b. If the alarm occurs repeatedly,
contact Huawei technical
support.
Reason ID = 20
a. Check whether the SUN2000
output cables are short-circuited.
Rectify any fault.
b. If the alarm occurs repeatedly,
contact Huawei technical
support.