Instruction Manual Supplement
D103790X012
SIS: Safety Instrumented System – Implementation of one or more Safety Instrumented Functions. A SIS is composed
of any combination of sensor(s), logic solver(s), and final element(s).
Related Literature
Hardware Documents:
Bulletin:
61.1:1052, Fisher 1051 and 10522 Diaphragm Rotary Actuators: D100089X012
Instruction Manual:
Fisher 1051 and 1052 Style F and G Size 40, 60, and 70 Rotary Actuators: D100319X012
Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation:
Fisher 1051 and 1052 Size 33 Diaphragm Rotary Actuators:
Guidelines/References:
D Safety Integrity Level Selection – Systematic Methods Including Layer of Protection Analysis, ISBN 1556177771,
ISA
D Control System Safety Evaluation and Reliability, 2nd Edition, ISBN 1556176388, ISA
D Safety Instrumented Systems Verification, Practical Probabilistic Calculations, ISBN 1556179099, ISA
Reference Standards
Functional Safety
D IEC 61508: 2010 Functional safety of electrical/electronic/ programmable electronic safetyrelated systems
D ANSI/ISA 84.00.012004 (IEC 61511 Mod.) Functional Safety – Safety Instrumented Systems for the Process Industry
Sector
Product Description
The Fisher 1052 is a spring and diaphragm rotary actuator.
The 1052 actuator can be installed on rotaryshaft valve bodies for throttling or onoff applications. The actuator
linkage features a clamped shaft lever and a single pivot point to reduce lost motion between the actuator and the
valve.
The 1052 actuator delivers several operations and maintenance advantages. It has an inherent failsafe position on loss
of operating air. In contrast to piston style actuators that rely on oring seals, the doublesided diaphragm in the 1052
actuator provides a longer service life.
Powder paint coating is standard and offers an excellent corrosionresistant finish on all external steel and cast iron
parts.
The 1052 actuator is used with a rotary valve to control process fluids that can be used in a wide variety of applications.
They are typically used with other interface components (valve positioner or solenoid valve) to provide a final element
subsystem for a SIF.
D100322X012
D101322X012
1052 Actuator
October 2017
3