Type Overview; Technical Data - AEG THYRO-S 1S*H 1 Series Operating Instructions Manual

Thyristor-switch
Hide thumbs Also See for THYRO-S 1S*H 1 Series:
Table of Contents

Advertisement

9. Type overview

9.1 Type 1S...H 1
Thyristor switches with incorporated semiconductor fuse and system
bus interface.
Type capacity [kW]
Current
230V 400V 500V Dissi-
Type
1S
pation
H 1
16
3.7
6.4
8
H 1
30
6.9
12
15
H 1
45
10
18
22.5
H 1
60
14
24
30
H 1
100
23
40
50
105
H 1
130
30
52
65
150
H 1
170
39
68
85
210
HF 1 280
64
112
140
330
9.2 Type 1S...H RL1
Thyristor switches with incorporated semiconductor, system bus in-
terface, additional 24V d.c./a.c. control voltage supply, relay indica-
tion and load current monitoring
Type capacity [kW]
Type
Current
230V 400V 500V
1S
pation
H RL 1
16
3,7
6,4
8
H RL 1
30
6,9
12
15
H RL 1
45
10
18
22,5
H RL 1
60
14
24
30
H RL 1
100
23
40
50
H RL 1
130
30
52
65
H RL 1
170
39
68
85
HF RL 1
280
64
112
140
Dimensions in mm / kg
W
H
E
Weight Dim.
Fuse
draw
F1
[W]
30
45
131
127
0.7
851
20
47
45
131
127
0.7
851
40
48
52
190
182
1.7
853
63
80
52
190
182
1.7
853
80
75
190
190
1.9
854
200
125
320
241
4
856
200
125
320
241
4
856
315
125
370
241
5
858
350
Dimensions in mm / kg
Dissi-
W
H
D Weight Dim.
Current
Fuse
draw
transf.
F1
[W]
30
45 131 127 0,7
851
40
20
47
45 131 127 0,7
851
40
40
48
52 190 182 1,7
853
100
63
80
52 190 182 1,7
853
100
80
105
75 190 190 1,9
854
100
200
150
125 320 241
4
856
150
200
210
125 320 241
4
856
200
315
330
125 370 241
5
856
300
350
84

10. Technical data

Type voltage
S..H1
230 Volt, 400 Volt, 500 Volt
– 57 % + 10 %;
S..HRL1
230 Volt – 15 % + 10 %;
> 99 V with additional 24 AC/DC elektronic power
400 Volt – 15 % + 10 %;
> 172 V with additional 24 AC/DC elektronic power
500 Volt – 15 % + 10 %;
> 215 V with additional 24 AC/DC elektronic power
Mains frequency all models 47Hz to 63Hz; i = 6Hz;
max. frequency change 5% per half wave
Load description ohmic load
Operating modes Name Load signal, with digital set point = ON
1:1
all full wave (default setting)
1:2
every 2. mains full wave (DC free)
1:3
every 3. mains full wave (DC free)
1:5
every 4. mains full wave (DC free)
Digital set points inputs (connection signals)
The Thyro-S has 2 set point inputs. The set point inputs
are safely disconnected from the mains (SELV, PELV).
Set point 1: Logic input 0-24V R
Set point 2: System interface, connection from superset
automation system via optional bus modu-
le.
Relay outputs using type 1S...H RL1
Changer, contact material: AgSnO2 / Au plated
The relay can be used for low load circuits (> 5V 20mA), however not
if it has been pre-loaded by 230V AC.
Maxiumum values: 250V 6A, 180W, 1500VA