Delta Electronics AFE075A43A User Manual page 71

Afe2000 series. active front end unit
Table of Contents

Advertisement

04 通訊參數
Parameter
Explanation
04-00
Communication Address
04-01
Transmission Speed
(Keypad)
04-02
Transmission Fault Treatment
(Keypad)
04-03
Time-out Detection (Keypad)
04-04
Communication Protocol
(Keypad)
04-05
Response Delay Time
04-06
COM2Transmission Speed
(Keypad)
04-07
COM2 Transmission Fault
Treatment (Keypad)
04-08
COM2 Time-out Detection
(Keypad)
04-09
COM2 Communication
Protocol (Keypad)
04-10
Communication Card Type
Chapter 10 Summary of Parameter SettingsAFE2000 Series
Settings
1~254
4.8~115.2Kbps
0: Warn and continue operation
1: Warn and ramp to stop
2: Reserved
3: No treatment and no warn
0.0~100.0 sec
0: 7N1 (ASCII)
1: 7N2 (ASCII)
2: 7E1 (ASCII)
3: 7O1 (ASCII)
4: 7E2 (ASCII)
5: 7O2 (ASCII)
6: 8N1 (ASCII)
7: 8N2 (ASCII)
8: 8E1 (ASCII)
9: 8O1 (ASCII)
10: 8E2 (ASCII)
11: 8O2 (ASCII)
12: 8N1 (RTU)
13: 8N2 (RTU)
14: 8E1 (RTU)
15: 8O1 (RTU)
16: 8E2 (RTU)
17: 8O2 (RTU)
0.0~200.0ms
4.8~115.2Kbps
0: Warning and continue to operate
1: Warn and ramp to stop
2: Warn and coast to stop
3: No warning and continue to operate
0.0~100.0 sec
0: 7N1 (ASCII)
1: 7N2 (ASCII)
2: 7E1 (ASCII)
3: 7O1 (ASCII)
4: 7E2 (ASCII)
5: 7O2 (ASCII)
6: 8N1 (ASCII)
7: 8N2 (ASCII)
8: 8E1 (ASCII)
9: 8O1 (ASCII)
10: 8E2 (ASCII)
11: 8O2 (ASCII)
12: 8N1 (RTU)
13: 8N2 (RTU)
14: 8E1 (RTU)
15: 8O1 (RTU)
16: 8E2 (RTU)
17: 8O2 (RTU)
0: No communication card
1: DeviceNet Slave
10-69
Factory
Setting
1
19.2
3
0
13
2
19.2
3
0.0
13
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents