A EX 2GD - Vacuum Cleaners
Items to inspect
VACUUM OFF
Suction hoses, couplings
Gaskets
Cartridge filter
Filter bag
Silencer material
Float ball
Ejector nozzle
Wear plate, silo
Wear plate, grit and dust
separator
VACUUM ON
If specified vacuum is not
reached
Abnormal noise level.
8
22
WARNING!
Risk of personal injury.
• Disconnect vacuum cleaner from compressed air before any type of service
or transportation.
• Be cautious when performing maintenance; there is a crush risk with a
pneumatic cylinder.
• Empty dust into a container or dust bag, see Figure 8.
• Do not place vacuum cleaner on an uneven surface.
• Always use proper protective equipment where there is a risk for exposure
to dust, see Figure 8.
• Wear an approved breathing mask, and do not spread dust when cleaning or
replacing filters, see Figure 8.
• Always use proper lifting equipment and protective gear.
What to look for
Leaking suction hoses and couplings.
Worn out, aged and leaking gaskets.
Worn out filters.
Full or torn filter bag.
Damaged silencing material.
Dirty float ball.
Dirty ejector nozzle.
Damaged or frayed rubber pad on the
wear plate.
See Section 9, Troubleshooting.

Spare parts

For spare parts, see the attached Spare Parts manual.
Service
Replace.
Replace.
Replace.
Clean or replace a full filter bag. Replace
a torn filter bag.
Replace.
Clean the float ball at least once a
month.
Clean.
Replace.